Background: In this review, we introduce the displacement encoding with stimulated echoes (DENSE) method for measuring myocardial dyssynchrony using cardiovascular magnetic resonance (CMR) imaging. We provide an overview of research findings related to DENSE from the past two decades and discuss other techniques used for dyssynchrony evaluation. Additionally, the review discusses the potential uses of DENSE in clinical practice. Methods: A search was conducted to identify relevant articles published from January 2000 through January 2023 using the Scopus, Web of Science, PubMed and Cochrane databases. The following search term was used: (DENSE OR ‘displacement encoding with stimulated echoes’ OR CURE) AND (dyssynchrony* OR asynchron* OR synchron*) AND (MRI OR ‘magnetic resonance’ OR CMR). Results: After removing duplicates, researchers screened a total of 174 papers. Papers that were not related to the topic, reviews, general overview articles and case reports were excluded, leaving 35 articles for further analysis. Of these, 14 studies focused on cardiac dyssynchrony estimation with DENSE, while the remaining 21 studies served as background material. The studies used various methods for presenting synchronicity, such as circumferential uniformity ratio estimate (CURE), CURE-singular value decomposition (SVD), radial uniformity ratio estimate (RURE), longitudinal uniformity ratio estimate (LURE), time to onset of shortening (TOS) and dyssynchrony index (DI). Most of the dyssynchrony studies concentrated on human heart failure, but congenital heart diseases and obesity were also evaluated. The researchers found that DENSE demonstrated high reproducibility and was found useful for detecting cardiac resynchronisation therapy (CRT) responders, optimising CRT device settings and assessing right ventricle synchronicity. In addition, studies showed a correlation between cardiac fibrosis and mechanical dyssynchrony in humans, as well as a decrease in the synchrony of contraction in the left ventricle in obese mice. Conclusions: DENSE shows promise as a tool for quantifying myocardial function and dyssynchrony, with advantages over other cardiac dyssynchrony evaluation methods. However, there remain challenges related to DENSE due to the relatively time-consuming imaging and analysis process. Improvements in imaging and analysing technology, as well as possible artificial intelligence solutions, may help overcome these challenges and lead to more widespread clinical use of DENSE.Keywords
Funding Information
- Emil Aaltonen Foundation
- Research Committee of the Kuopio University Hospital Catchment Area for the State Research Funding (5063584, 5063586)
This publication has 73 references indexed in Scilit:
- Echocardiography-Guided Left Ventricular Lead Placement for Cardiac Resynchronization TherapyCirculation: Heart Failure, 2013
- Reproducibility of cine displacement encoding with stimulated echoes (DENSE) cardiovascular magnetic resonance for measuring left ventricular strains, torsion, and synchrony in miceJournal of Cardiovascular Magnetic Resonance, 2013
- Mapping right ventricular myocardial mechanics using 3D cine DENSE cardiovascular magnetic resonanceJournal of Cardiovascular Magnetic Resonance, 2012
- A Prospective Pilot Study to Evaluate the Relationship Between Acute Change in Left Ventricular Synchrony After Cardiac Resynchronization Therapy and Patient Outcome Using a Single-Injection Gated SPECT ProtocolCirculation: Cardiovascular Imaging, 2011
- Comprehensive Cardiovascular magnetic resonance of myocardial mechanics in mice using three-dimensional cine DENSEJournal of Cardiovascular Magnetic Resonance, 2011
- Imaging three‐dimensional myocardial mechanics using navigator‐gated volumetric spiral cine DENSE MRIMagnetic Resonance in Medicine, 2010
- Reconstruction of myocardial tissue motion and strain fields from displacement-encoded MR imagingAmerican Journal of Physiology-Heart and Circulatory Physiology, 2009
- Impact of viability and scar tissue on response to cardiac resynchronization therapy in ischaemic heart failure patientsEuropean Heart Journal, 2006
- The Seattle Heart Failure ModelCirculation, 2006
- Real‐time imaging of two‐dimensional cardiac strain using a harmonic phase magnetic resonance imaging (HARP‐MRI) pulse sequenceMagnetic Resonance in Medicine, 2003