Second derivative synchronous fluorescence determination of avanafil in the presence of its acid-induced degradation product aided by powerful Lean Six Sigma tools augmented with D-optimal design
Open Access
- 19 January 2021
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 11 (7) , 3834-3842
Abstract
In this work, the quantitative determination of an erectile dysfunctional drug avanafil in the presence of its acid-induced degradation product was achieved via the application of a pre-optimized novel spectrofluorimetric method. The fluorescence emission wavelength was recorded at 370 and 407 nm, after being excited at 268 and 271 nm for avanafil and its acid-induced degradation product, respectively. Direct determination of avanafil based on its native fluorescence is restricted because the emission spectra of both components are heavily overlapped. Therefore, to overcome this constraint, a novel second derivative synchronous fluorescence method was evolved to eliminate this overlapping. The ideal determination wavelength was found to be 377 nm. Augmentation of lean six sigma (LSS) with response surface methodology (RSM) play a significant role in the development of robust specifications to ensure quality at the six sigma level with a high level of statistical confidence and targeted performance. All of the experimental conditions were optimized using D-optimal design as a RSM to select the optimal parameters. In addition, this work includes a graphical representation of the relationships between various variables that can greatly affect the results and the intensity of the synchronous fluorescence.Keywords
This publication has 34 references indexed in Scilit:
- An open-label, long-term evaluation of the safety, efficacy and tolerability of avanafil in male patients with mild to severe erectile dysfunctionInternational Journal Of Clinical Practice, 2013
- Avanafil for the Treatment of Erectile Dysfunction: A Multicenter, Randomized, Double-Blind Study in Men With Diabetes MellitusMayo Clinic Proceedings, 2012
- A Randomized, Double‐Blind, Placebo‐Controlled Evaluation of the Safety and Efficacy of Avanafil in Subjects with Erectile DysfunctionThe Journal of Sexual Medicine, 2012
- Avanafil, a new rapid-onset phosphodiesterase 5 inhibitor for the treatment of erectile dysfunctionExpert Opinion on Investigational Drugs, 2010
- Lean Six Sigma – getting better all the timeInternational Journal of Lean Six Sigma, 2010
- Chemometric tools in electroanalytical chemistry: Methods for optimization based on factorial design and response surface methodologyMicrochemical Journal, 2009
- Response surface methodology (RSM) as a tool for optimization in analytical chemistryTalanta, 2008
- Simultaneous determination of carvedilol and ampicillin sodium by synchronous fluorimetrySpectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2005
- Recent developments in multi-component synchronous fluorescence scan analysisTrAC Trends in Analytical Chemistry, 2002
- Determination of thiamine, riboflavin and pyridoxine in pharmaceuticals by synchronous fluorescence spectrometry in organized mediaAnalytica Chimica Acta, 2001