Only serum pepsinogen I and pepsinogen I/II ratio are specific and sensitive biomarkers for screening of gastric cancer

Authors:

Abstract
Purpose: We aimed to determine optimal cut-off points of plasma levels of ghrelin and serum levels of pepsinogen I, II, and their ratio for screening of gastric cancer (GC). Methods: Blood samples were taken from 41 patients with confirmed gastric cancer along with 82 patients without malignancy. Serum levels of pepsinogen I and II, plus plasma levels of acylated ghrelin were measured using commercial ELISA kits. Results: The case group had significant lower plasma levels of ghrelin, pepsinogen I, and pepsinogen I/II ratio in comparison to the control group (P<0.001). In the control group, there was significant higher serum pepsinogen I (P=0.028) and pepsinogen II (P=0.003) and lower pepsinogen I/II ratio (P=0.020) in males versus females; significantly higher serum pepsinogen II (P=0.047) and lower pepsinogen I/II ratio (P=0.030) in overweight compared to normal weight patients; and significantly lower pepsinogen I/II ratio (P=0.030) in smokers versus non-smoker. In the case group, there was only significantly lower pepsinogen I (P=0.006) in males versus females, and significantly lower plasma ghrelin (P=0.017) in overweight compared to normal weight patients. The characteristic curve analysis indicated that pepsinogen I at a cut-off of 70.95 μg/L and pepsinogen I/II ratio at cut-off of 2.99, had good sensitivity and specificity. Conclusions: Just serums levels of pepsinogen I and the ratio of pepsinogen I/II can be used as biomarker to screen GC.

This publication has 46 references indexed in Scilit: