Revisiting the Sequence Method for Baroreflex Analysis
Authors:
Open Access
- 23 January 2019
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 13, 17
Abstract
The sequence method is an important approach to assess the baroreflex function, mainly because it is based on the spontaneous fluctuations of beat-by-beat arterial pressure (for example, systolic arterial pressure or SAP) and pulse interval (PI). However, some studies revealed that the baroreflex effectiveness index (BEI), calculated through the sequence method, shows an intriguing oscillatory pattern as function of the delay between SAP and PI. It has been hypothesized that this pattern is related to the respiratory influence on SAP and/or PI variability, limiting the SAP ramps to 3 or 4 beats of length. In this study, this hypothesis was tested by assessing the sequence method using raw (original) and filtered series. Results were contrasted to the well-established transfer function, estimated between SAP and PI. Continuous arterial pressure recordings were obtained from healthy rats (N = 61) and beat-by-beat series of SAP and PI were generated. Low-pass (LP) and high-pass (HP) filtered series of SAP and PI were created by filtering the original series with a cutoff frequency of 0.8 Hz. Original series were analyzed by either the sequence method or cross-spectral analysis (transfer function) at low- (LF) and high- (HF) frequency bands, while filtered series were evaluated only by the sequence method. Baroreflex sensitivity (BRS) and BEI of original series, calculated by sequence method, was highly (85–90%) determined by HP series, with no significant association between original and LP series. A high correlation (>0.7) was found between the BRS estimated from original series (sequence method) and HF band (transfer function), as well as for LP series (sequence method) and LF band (transfer function). These findings confirmed the hypothesis that the sequence method quantifies only the high-frequency components of the baroreflex, neglecting the low-frequency influences, such as the Mayer waves. Therefore, we propose using both the original and LP filtered time series for a broader assessment of the baroreflex function using the sequence method.Keywords
Funding Information
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
- Fundação de Amparo à Pesquisa do Estado de São Paulo
- Conselho Nacional de Desenvolvimento Científico e Tecnológico
This publication has 32 references indexed in Scilit:
- Cardiovascular control and time domain Granger causality: insights from selective autonomic blockadePhilosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2013
- Information Domain Approach to the Investigation of Cardio-Vascular, Cardio-Pulmonary, and Vasculo-Pulmonary Causal CouplingsFrontiers in Physiology, 2011
- Baroreflex Sensitivity: Measurement and Clinical ImplicationsAnnals of Noninvasive Electrocardiology, 2008
- BAROREFLEX CONTROL OF SYMPATHETIC NERVE ACTIVITY AND BLOOD PRESSURE VARIABILITYClinical and Experimental Pharmacology and Physiology, 2008
- Applicability of recent methods used to estimate spontaneous baroreflex sensitivity to resting miceAmerican Journal of Physiology-Regulatory, Integrative and Comparative Physiology, 2008
- Baroreceptor Reflex Sensitivity Estimated by the Sequence Technique is Reliable in RatsAmerican Journal of Physiology-Heart and Circulatory Physiology, 2006
- Automation of analysis of cardiovascular autonomic function from chronic measurements of arterial pressure in conscious ratsExperimental Physiology, 2005
- Causal Cross-Spectral Analysis of Heart Rate and Blood Pressure Variability for describing the Impairment of the Cardiovascular Control in Neurally Mediated SyncopeIEEE Transactions on Biomedical Engineering, 2005
- Frequency-dependent baroreflex modulation of blood pressure and heart rate variability in conscious miceAmerican Journal of Physiology-Heart and Circulatory Physiology, 2005
- Comparison of various techniques used to estimate spontaneous baroreflex sensitivity (the EuroBaVar study)American Journal of Physiology-Regulatory, Integrative and Comparative Physiology, 2004