Validation of Echodynamography in Comparison with Particle-image Velocimetry
Authors:
- 16 October 2019
- journal article
- research article
- Published by SAGE Publications in Ultrasonic Imaging
- Vol. 41 (6) , 336-352
Abstract
Echodynamography (EDG) is a computational method to estimate and visualize two-dimensional flow velocity vectors by applying dynamic flow theories to color Doppler echocardiography. The EDG method must be validated if applied to human cardiac flow function. However, a few studies of flow estimated have compared by EDG to the flow data were acquired by other methods. In this study, EDG was validated by comparing the analysis of estimating and visualizing flow velocity vectors obtained by original particle image velocimetry (PIV) based on a left ventricular (LV) phantom hydrogel (in vitro studies) and by EDG based on the virtual Doppler velocity. Velocity measured by PIV method and velocity estimated by EDG method in the perpendicular direction and the radial direction were compared. Regression analysis for the velocity estimated in the radial direction revealed an excellent correlation ( , slope = 0.96) and moderate correlation in the perpendicular direction ( , slope = 0.46). As revealed by the Bland–Altman plot, however, overestimations and higher relative error were observed in the perpendicular direction (0.51 ± 2.75 mm/s) and in the radial direction (–2.15 ± 21.13 mm/s). The percentage error of the norm-wise relative error of the velocity discrepancy is less than , and velocity magnitude followed the same trends and are of comparable magnitude. These findings indicate that good estimates of velocity can be obtained by the EDG method. Therefore, the EDG method was appropriate for estimating and visualizing velocity vectors in clinical studies for higher measurement accuracy and reliability. The clinical in vivo application showed that the EDG method has the ability to visualize blood flow velocity vectors and differentiate the clinical information of vortex parameters both in normal and abnormal LV subjects. In conclusion, the EDG method has potentially greater clinical acceptance as a tool assessment of LV during the cardiac cycle.
Keywords
This publication has 26 references indexed in Scilit:
- Stiffness, Compliance, Resilience, and Creep Deformation: Understanding Implant-Soft Tissue Dynamics in the Augmented Breast: Fundamentals Based on Materials ScienceAesthetic Plastic Surgery, 2013
- Physiological basis and clinical significance of left ventricular suction studied using echo-dynamographyJournal of Cardiology, 2011
- Spiral systolic blood flow in the ascending aorta and aortic arch analyzed by echo-dynamographyJournal of Cardiology, 2010
- Left ventricular flow patterns in healthy subjects and patients with prosthetic mitral valves: An in vivo study using echocardiographic particle image velocimetryThe Journal of Thoracic and Cardiovascular Surgery, 2010
- A New Echocardiographic Method for Identifying Vortex Flow in the Left Ventricle: Numerical ValidationUltrasound in Medicine & Biology, 2010
- Echocardiographic Particle Image Velocimetry: A Novel Technique for Quantification of Left Ventricular Blood Vorticity PatternJournal of the American Society of Echocardiography, 2010
- Doppler echocardiography: A contemporary reviewJournal of Cardiology, 2009
- A Dual-Phantom System for Validation of Velocity Measurements in Stenosis Models Under Steady FlowUltrasound in Medicine & Biology, 2009
- Characterization and Quantification of Vortex Flow in the Human Left Ventricle by Contrast Echocardiography Using Vector Particle Image VelocimetryJACC: Cardiovascular Imaging, 2008
- Tissue Doppler imaging: current and potential clinical applicationsHeart, 2000