Theoretical study of the fibrous capsule tissue growth around a disk-shaped implant
- 19 August 2012
- journal article
- research article
- Published by Springer Nature in Journal of Mathematical Biology
- Vol. 67 (4) , 833-867
Abstract
We analyze the mathematical properties of the fibrous capsule tissue concentration around a disk-shaped implant. We establish stability estimates as well as monotonicity results that illustrate the sensitivity of this growth to the biocompatibility index parameters of the implant. In addition, we prove that the growth of the tissue increases exponentially in time toward an asymptotic regime. We also study the mathematical properties of the solution of the inverse problem consisting in the determination of the values of the biocompatibility index parameters from the knowledge of some fibrous capsule tissue measurements. We prove that this model calibration problem admits a unique solution, and establish a characterization of the index parameters. Furthermore, we demonstrate analytically that such a solution is not continuous with respect to the data, and therefore the considered inverse problem is ill-posed due to the lack of the stability requirement.Keywords
This publication has 11 references indexed in Scilit:
- Modeling capsule tissue growth around disk-shaped implants: a numerical and in vivo studyJournal of Mathematical Biology, 2008
- Biodegradable polydioxanone and poly(l/d)lactide implants: an experimental study on peri-implant tissue responseInternational Journal of Oral and Maxillofacial Surgery, 2005
- Cytological evaluation of the tissue–implant reaction associated with subcutaneous implantation of polymers coated with titaniumcarboxonitride in vivoBiomaterials, 2004
- Tissue response to microfibers of different polymers: Polyester, polyethylene, polylactic acid, and polyurethaneJournal of Biomedical Materials Research, 2002
- Biological Responses to MaterialsAnnual Review of Materials Research, 2001
- Long- and short-term effects of biological hydrogels on capsule microvascular density around implants in ratsJournal of Biomedical Materials Research, 2001
- Thickness of fibrous capsule after implantation of hydroxyapatite in subcutaneous tissue in ratsJournal of Biomedical Materials Research, 1999
- Long-term observation of subcutaneous tissue reaction to synthetic auditory ossicle (Bioceram) in rats.1999
- Partial Differential Equations1991
- Semigroups of Linear Operators and Applications to Partial Differential Equations1983