Fluorescence-Based Quantification of Gastrointestinal Perfusion: A Step Towards an Automated Approach
- 1 March 2022
- journal article
- research article
- Published by SAGE Publications in Journal of Laparoendoscopic & Advanced Surgical Techniques
- Vol. 32 (3) , 293-298
Abstract
Background: Qualitative fluorescence angiography (FA) provides insights into intestinal tissue perfusion, but today it is not yet accurate in predicting anastomotic leakage. To improve peroperative detection of impaired perfusion, quantified parameters should be investigated using a standardized method. The aim of this study was to develop a (semi)automated algorithm for comprehensive and convenient analysis of FA parameters. Materials and Methods: An analysis tool was developed for the extraction of quantified FA parameters. The start- and endpoint of intensity increase (T0 and ) were automatically detected in the intensity–time curves. Algorithm performance was measured against manual assignment of T0 and by 9 independent observers in 18 in vivo generated test signals, using the intraclass correlation coefficient (ICC). Characteristics of parameter (time to 50% of maximal intensity) were analyzed in normally perfused small intestine of 32 subjects who underwent robotic laparoscopic surgery. Since ethical approval was not required under the Dutch law, the need for informed consent was waived. Results: Automated detection of T0 and was successful in all subjects. Output of the algorithm had an excellent agreement with the median of the human observations: ICC = 0.95 (95% confidence interval: 0.86–0.96). Overall, had a median value of 5.1 (interquartile range = 2.4) seconds and a minimal and maximal value of 1.3 and 9.9 seconds, respectively. Conclusions: The presented method provided convenient data analysis in the search for effective FA quantification. Future research should expand the data to find adequate threshold values for peroperatively identifying insufficient perfusion and investigate the influence of physiological conditions.Keywords
This publication has 23 references indexed in Scilit:
- Evaluation of intestinal perfusion by ICG fluorescence imaging in laparoscopic colorectal surgery with DST anastomosisSurgical Endoscopy, 2016
- Indocyanine green fluorescence angiography for intraoperative assessment of gastrointestinal anastomotic perfusion: a systematic review of clinical trialsLangenbeck's Archives of Surgery, 2016
- Morbidity, Mortality, Cost, and Survival Estimates of Gastrointestinal Anastomotic LeaksJournal of the American College of Surgeons, 2015
- Perfusion Assessment in Laparoscopic Left-Sided/Anterior Resection (PILLAR II): A Multi-Institutional StudyJournal of the American College of Surgeons, 2015
- Enhanced-Reality Video FluorescenceAnnals of Surgery, 2014
- Predicting the survival of experimental ischaemic small bowel using intraoperative near-infrared fluorescence angiographyBritish Journal of Surgery, 2011
- How to assess intestinal viability during surgery: A review of techniquesWorld Journal of Gastrointestinal Surgery, 2011
- Surgeons lack predictive accuracy for anastomotic leakage in gastrointestinal surgeryInternational Journal of Colorectal Disease, 2009
- Colonic Anastomotic Leak: Risk Factors, Diagnosis, and TreatmentJournal of the American College of Surgeons, 2009
- The incidence of anastomotic leaks in patients undergoing colorectal surgeryColorectal Disease, 2006