Start-Up Evaluation of a Full-Scale Wastewater Treatment Plant Consisting of a UASB Reactor Followed by Activated Sludge
Open Access
Abstract
UASB (upflow anaerobic sludge blanket) reactors have been recognized as a viable option for sewage treatment. However, in order to improve the UASB effluent quality, some type of post-treatment must be implemented. The aims of this study were (i) to establish a start-up methodology of a full-scale anaerobic–aerobic system treating sewage, (ii) to evaluate the concentrations of different constituents in the influent and effluent of the anaerobic and aerobic reactors as well as the removal efficiencies in every step of the system, and (iii) to define relevant operative aspects of the anaerobic and aerobic reactors. The Tunja (Colombia) wastewater treatment plant consists of three modules with preliminary treatment followed by UASB reactors with post-treatment of activated sludge. The results of this investigation showed that the effluent system meets the Colombian environmental legislation with average removal efficiency values of BOD (88 +/− 5%), COD (87 +/− 4%), and TSS (94 +/− 5%). The UASB reactor start-up was conducted without an inoculum, requiring a period of 120 days. The evaluation of the combined systems was conducted over 300 days. Moreover, a methodology to operate the system during and after the start-up of the anaerobic reactor was defined. It was demonstrated that the anaerobic effluent can deteriorate the sludge in the aerobic tank. In order to avoid this, important operational aspects must be considered during the operation of the system, such as the implementation of a raw wastewater bypass higher than 15% and monitoring of the anaerobic effluent settleable solid concentration (<0.3 mL/L).Keywords
Funding Information
- Veolia-Tunja and Universidad de Boyaca (20_2020)
This publication has 35 references indexed in Scilit:
- Sequential anaerobic–aerobic treatment for domestic wastewater – A reviewBioresource Technology, 2010
- A review on anaerobic–aerobic treatment of industrial and municipal wastewaterChemical Engineering Journal, 2009
- Coupled UASB-activated sludge process for COD and nitrogen removals in municipal sewage treatment in warm climateWater Science & Technology, 2009
- Efeito do retorno de lodo aeróbio sobre as características da biomassa presente em reatores UASB tratando esgoto sanitárioEngenharia Sanitaria e Ambiental, 2009
- Performance evaluation of UASB reactor systems with and without post-treatmentWater Science & Technology, 2009
- Comparative performance evaluation of full-scale anaerobic and aerobic wastewater treatment processes in BrazilWater Science & Technology, 2009
- Optimization of the performance of an integrated anaerobic–aerobic system for domestic wastewater treatmentWater Science & Technology, 2008
- Control Strategies for a Combined Anaerobic (UASB) – Aerobic (Activated Sludge) Wastewater Treatment SystemEnvironmental Technology, 2005
- A review: The anaerobic treatment of sewage in UASB and EGSB reactorsBioresource Technology, 1998
- Treatment of raw domestic sewage in an UASB reactorWater Research, 1989