Tolerances on MLC leaf position accuracy for IMRT delivery with a dynamic MLC
Authors:
- Alejandra RangelARAlejandra Rangel
- Peter DunscombePDPeter Dunscombe
- 19 June 2009
- journal article
- Published by Wiley in Medical Physics
- Vol. 36 (7) , 3304-3309
Abstract
The objective determination of performance standards for radiation therapy equipment requires, ideally, establishing the quantitative relationship between performance deviations and clinical outcome or some acceptable surrogate. In this simulation study the authors analyzed the dosimetric impact of random (leaf by leaf) and systematic (entire leaf bank) errors in the position of the MLC leaves on seven clinical prostate and seven clinical head and neck IMRT plans delivered using a dynamic MLC. In‐house software was developed to incorporate normally distributed errors of up to ±2 mm in individual leaf position or systematic errors (±1 and ±0.5 mm in all leaves of both leaf banks or in one bank only) into the 14 plans, thus simulating treatment delivery using a suboptimally performing MLC. The dosimetric consequences of suboptimal MLC performance were quantified using the equivalent uniform doses (EUDs) of the clinical target volumes and important organs at risk (OARs). The deviation of the EUDs of the selected structures as the performance of the MLC deteriorated was used as the objective surrogate of clinical outcome. Random errors of 2 mm resulted in negligible changes for all structures of interest in both sites. In contrast, systematic errors can lead to potentially significant dosimetric changes that may compromise clinical outcome. If a 2% change in EUD of the target and 2 Gy for the OARs were adopted as acceptable levels of deviation in dose due to MLC effects alone, then systematic errors in leaf position will need to be limited to 0.3 mm. This study provides guidance, based on a dosimetric surrogate of clinical outcome, for the development of one component, leaf position accuracy of performance standards for multileaf collimators.Keywords
This publication has 26 references indexed in Scilit:
- MLC quality assurance using EPID: A fitting technique with subpixel precisionMedical Physics, 2008
- Impact of MLC leaf position errors on simple and complex IMRT plans for head and neck cancerPhysics in Medicine & Biology, 2007
- Evaluation of MLC leaf positioning using a scanning liquid ionization chamber EPIDPhysics in Medicine & Biology, 2006
- Use of an amorphous silicon electronic portal imaging device for multileaf collimator quality control and calibrationPhysics in Medicine & Biology, 2005
- MLC quality assurance techniques for IMRT applicationsMedical Physics, 2003
- Communication and sampling rate limitations in IMRT delivery with a dynamic multileaf collimator systemMedical Physics, 2002
- Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic modeMedical Physics, 2001
- Requirements for leaf position accuracy for dynamic multileaf collimationPhysics in Medicine & Biology, 2000
- Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapyMedical Physics, 1998
- Testing of dynamic multileaf collimationMedical Physics, 1996