High precision measurements of gallium isotopic compositions in geological materials by MC-ICP-MS
- 5 July 2016
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 31 (8) , 1673-1679
Abstract
An analytical protocol for the accurate and precise determination of the gallium isotope ratio in geological materials is presented for the first time by using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). Separation of Ga from natural sample matrices was achieved by using a three-column ion-exchange chromatograph with one anion exchange AG MP-1M column and two cation exchange AG 50W-X8 columns. This approach provides an efficient purification with a low blank and high yield of Ga from an excess amount of Fe existing in geological samples. The instrument mass bias was monitored and corrected by using a model of standard-sample bracketing with internal normalization, and copper was used as an internal standard which was added to both the sample and standard solutions. The long-term external reproducibility of δ71/69Ga obtained is 0.04‰ (2SD). Ga isotopic compositions of geological reference materials including basalt, andesite, rhyolite, granodiorite, soil, sediment, carbonatite and shale were measured using the proposed approach. The 71Ga/69Ga ratio in these geological reference materials spanned over a rather narrow range between 0.74‰ and 0.90‰, relative to NIST SRM 994.Keywords
Funding Information
- National Natural Science Foundation of China (41273005 and 41473007)
This publication has 38 references indexed in Scilit:
- An extraction study of gallium, indium, and zinc with mixtures of sec-octylphenoxyacetic acid and primary amine N1923Separation and Purification Technology, 2011
- Resolving the Germanium Atomic Weight Disparity Using Multicollector ICPMSAnalytical Chemistry, 2010
- Gallium: the backbone of the electronics industryMinerals Engineering, 2003
- Precise analysis of copper and zinc isotopic compositions by plasma-source mass spectrometryChemical Geology, 1999
- Genotoxicity of beryllium, gallium and antimony in short-term assaysMutation Research Letters, 1991
- Environmental and workplace contamination in the semiconductor industry: implications for future health of the workforce and community.Environmental Health Perspectives, 1990
- Isotopic fractionation of gallium on an ion-exchange columnAnalytical Chemistry, 1988
- Isotopic variations in commercial high-purity galliumAnalytical Chemistry, 1985
- A Mass-Spectrograph Study of Ba, Sr, In, Ga, Li, and NaPhysical Review B, 1936
- The isotopic constitution and atomic weights of hafnium, thorium, rhodium, titanium, zirconium, calcium, gallium, silver, carbon, nickel, cadmium, iron and indiumProceedings of the Royal Society of London. A. Mathematical and Physical Sciences, 1935