SLfRank: Shinnar-Le-Roux Pulse Design With Reduced Energy and Accurate Phase Profiles Using Rank Factorization
- 28 December 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 42 (5) , 1522-1531
Abstract
The Shinnar-Le-Roux (SLR) algorithm is widely used to design frequency selective pulses with large flip angles. We improve its design process to generate pulses with lower energy (by as much as 26%) and more accurate phase profiles. Concretely, the SLR algorithm consists of two steps: (1) an invertible transform between frequency selective pulses and polynomial pairs that represent Cayley-Klein (CK) parameters and (2) the design of the CK polynomial pair to match the desired magnetization profiles. Because the CK polynomial pair is bi-linearly coupled, the original algorithm sequentially solves for each polynomial instead of jointly. This results in sub-optimal pulses. Instead, we leverage a convex relaxation technique, commonly used for low rank matrix recovery, to address the bilinearity. Our numerical experiments show that the resulting pulses are almost always globally optimal in practice. For slice excitation, the proposed algorithm results in more accurate linear phase profiles. And in general the improved pulses have lower energy than the original SLR pulses.Keywords
All Related Versions
Funding Information
- NIH (R01EB009690, U01EB029427)
This publication has 17 references indexed in Scilit:
- Improving diffusion MRI using simultaneous multi-slice echo planar imagingNeuroImage, 2012
- Radiofrequency pulse designs for three‐dimensional MRI providing uniform tipping in inhomogeneous B1 fieldsMagnetic Resonance in Medicine, 2011
- Exact half pulse synthesis via the inverse scattering transformJournal of Magnetic Resonance, 2004
- Introduction to magnetic resonance imaging for mathematiciansAnnales de l'institut Fourier, 2004
- Improved approximation algorithms for maximum cut and satisfiability problems using semidefinite programmingJournal of the ACM, 1995
- Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm (NMR imaging)IEEE Transactions on Medical Imaging, 1991
- The synthesis of soft pulses with a specified frequency responseMagnetic Resonance in Medicine, 1989
- The use of finite impulse response filters in pulse designMagnetic Resonance in Medicine, 1989
- The synthesis of pulse sequences yielding arbitrary magnetization vectorsMagnetic Resonance in Medicine, 1989
- The application of spinors to pulse synthesis and analysisMagnetic Resonance in Medicine, 1989