Aim of this study was to compare a minimally fluoroscopic radiofrequency catheter ablation with conventional fluoroscopy-guided ablation for supraventricular tachycardias (SVTs) in terms of ionizing radiation exposure for patient and operator and to estimate patients' lifetime attributable risks associated with such exposure. We performed a prospective, multicentre, randomized controlled trial in six electrophysiology (EP) laboratories in Italy. A total of 262 patients undergoing EP studies for SVT were randomized to perform a minimally fluoroscopic approach (MFA) procedure with the EnSiteTMNavXTM navigation system or a conventional approach (ConvA) procedure. The MFA was associated with a significant reduction in patients' radiation dose (0 mSv, iqr 0–0.08 vs. 8.87 mSv, iqr 3.67–22.01; P < 0.00001), total fluoroscopy time (0 s, iqr 0–12 vs. 859 s, iqr 545–1346; P < 0.00001), and operator radiation dose (1.55 vs. 25.33 µS per procedure; P < 0.001). In the MFA group, X-ray was not used at all in 72% (96/134) of cases. The acute success and complication rates were not different between the two groups (P = ns). The reduction in patients' exposure shows a 96% reduction in the estimated risks of cancer incidence and mortality and an important reduction in estimated years of life lost and years of life affected. Based on economic considerations, the benefits of MFA for patients and professionals are likely to justify its additional costs. This is the first multicentre randomized trial showing that a MFA in the ablation of SVTs dramatically reduces patients' exposure, risks of cancer incidence and mortality, and years of life affected and lost, keeping safety and efficacy. clinicaltrials.gov Identifier: NCT01132274.Keywords
This publication has 33 references indexed in Scilit:
- Exclusion of Fluoroscopy Use in Catheter Ablation Procedures: Six Years of Experience at a Single CenterJournal of Cardiovascular Electrophysiology, 2014
- Canadian Cardiovascular Society Position Statement on Radiation Exposure From Cardiac Imaging and Interventional ProceduresCanadian Journal of Cardiology, 2013
- “Near-zero” fluoroscopic exposure in supraventricular arrhythmia ablation using the EnSite NavX™ mapping system: personal experience and review of the literatureJournal of Interventional Cardiac Electrophysiology, 2011
- Safety and feasibility of catheter ablation for atrioventricular nodal re-entrant tachycardia without fluoroscopic guidanceHeart Rhythm, 2009
- Elimination of Fluoroscopy Use in a Pediatric Electrophysiology Laboratory Utilizing Three‐Dimensional MappingPacing and Clinical Electrophysiology, 2007
- Nonfluoroscopic Catheter Navigation for Radiofrequency Catheter Ablation of Supraventricular Tachycardia in ChildrenPacing and Clinical Electrophysiology, 2006
- Reduction of fluoroscopy exposure and procedure duration during ablation of atrial fibrillation using a novel anatomical navigation system†European Heart Journal, 2005
- Catheter Ablation of Common‐Type Atrial Flutter Guided by Three‐Dimensional Right Atrial Geometry Reconstruction and Catheter Tracking Using Cutaneous Patches:Journal of Cardiovascular Electrophysiology, 2004
- Radiation exposure to medical staff in interventional and cardiac radiology.British Journal of Radiology, 1998
- Computation of bremsstrahlung X-ray spectra and comparison with spectra measured with a Ge(Li) detectorPhysics in Medicine & Biology, 1979