Improving cooling energy efficiency in Hong Kong offices using demand-controlled ventilation (DCV) and adaptive comfort temperature (ACT) systems to provide indoor environmental quality (IEQ) acceptance
Authors:
- 3 April 2017
- journal article
- research article
- Published by The Hong Kong Institution of Engineers in HKIE Transactions
- Vol. 24 (2) , 78-87
Abstract
Space cooling is a significant energy consumer in office buildings in the subtropical climate zone. An adequate energy policy for indoor spaces should accordingly incorporate both energy conservation and an acceptable level of indoor environmental quality (IEQ). This study investigates the cooling energy consumption for IEQ acceptance in Hong Kong offices adopted for four space-cooling strategies: the ventilation strategies of conventional constant air volume (CAV) systems with a fixed fresh air flow rate; demand-controlled ventilation (DCV) by indoor CO2 concentration; adaptive comfort temperature (ACT) set-point adjustment; and a combination of DCV and ACT operations. Numerical equations and multiple regression formulae were used to evaluate the cooling energy consumption and IEQ acceptance in the target offices, respectively. The results show that systems equipped with DCV are more energy efficient than conventional CAV systems, while a temperature set-point adjusted between 22°C and 23°C should satisfy the occupants’ thermal requirements at a reasonable rate of energy expenditure. Meanwhile, the DCV + ACT method was found to be an effective ventilation strategy in terms of its energy saving potential (21.4%--24.3%) and an “average” IEQ acceptance, as presented in the sample office. The results of this study could be useful for the promotion of energy saving measures with IEQ consideration in air-conditioned office buildings in Hong Kong.Keywords
Funding Information
- the HKSAR government (K-ZJJV)
This publication has 13 references indexed in Scilit:
- Implementation of adaptive indoor comfort temperature control via embedded system for air-conditioning unitJournal of Mechanical Science and Technology, 2012
- Decoupling dehumidification and cooling for energy saving and desirable space air conditions in hot and humid Hong KongEnergy Conversion and Management, 2012
- Influence of building parameters and HVAC systems coupling on building energy performanceEnergy and Buildings, 2011
- Adaptive generalised predictive temperature control for air conditioning systemsIET Control Theory & Applications, 2011
- The effects of air temperature on office workers’ well-being, workload and productivity-evaluated with subjective ratingsApplied Ergonomics, 2010
- An energy performance assessment for indoor environmental quality (IEQ) acceptance in air-conditioned officesEnergy Conversion and Management, 2009
- Indoor Environmental Quality in LEED-Certified Buildings in the U.S.Journal of Asian Architecture and Building Engineering, 2008
- Energy policy for integrating the building environmental performance model of an air conditioned building in a subtropical climateEnergy Conversion and Management, 2006
- Adaptive comfort temperature model of air-conditioned building in Hong KongBuilding and Environment, 2003
- Selection of an “example weather year” for Hong KongEnergy and Buildings, 1993