Serial Isotropic Three-Dimensional Fast FLAIR Imaging: Using Image Registration and Subtraction to Reveal Active Multiple Sclerosis Lesions
- 1 September 2002
- journal article
- clinical trial
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 179 (3) , 777-782
Abstract
OBJECTIVE. Image registration and subtraction to detect the change of disease burden in multiple sclerosis on serial MR images should benefit from the use of high-resolution isotropic voxels. We compared 1.2-mm isotropic three-dimensional (3D) fast fluid-attenuated inversion recovery (FLAIR) images with standard 3-mm two-dimensional spin-echo images for the detection of new or enlarging lesions in longitudinal studies.SUBJECTS AND METHODS. Serial MR images were obtained at baseline, month 6 (n = 20), and month 7 (n = 16). For the half-yearly intervals, subtracted 3D FLAIR images and T2-weighted spin-echo images were compared. For the monthly intervals, subtracted 3D FLAIR images were compared with triple-dose contrast-enhanced T1-weighted spin-echo images. New, enlarging, and enhancing lesions were marked in consensus by two radiologists.RESULTS. At the half-yearly intervals, 3D FLAIR imaging detected more new or enlarging lesions than T2-weighted spin-echo imaging, both at the initial interpretation (80 ...Keywords
This publication has 22 references indexed in Scilit:
- Image registration and subtraction to detect active T 2 lesions in MS: an interobserver studyJournal of Neurology, 2002
- Isotropic 3D fast FLAIR imaging of the brain in multiple sclerosis patients: initial experienceEuropean Radiology, 2002
- Improved interobserver agreement for visual detection of active T2 lesions on serial MR scans in multiple sclerosis using image registrationJournal of Neurology, 2001
- Visual analysis of serial T2-weighted MRI in multiple sclerosis: intra- and interobserver reproducibilityNeuroradiology, 1999
- Guidelines for using quantitative measures of brain magnetic resonance imaging abnormalities in monitoring the treatment of multiple sclerosisAnnals of Neurology, 1998
- The effect of imprecise repositioning on lesion volume measurements in patients with multiple sclerosisNeurology, 1997
- Strategies for optimizing MRI techniques aimed at monitoring disease activity in multiple sclerosis treatment trialsJournal of Neurology, 1997
- Lesion volume measurement in multiple sclerosis: How important is accurate repositioning?Journal of Magnetic Resonance Imaging, 1996
- Guidelines for the use of magnetic resonance techniques in monitoring the treatment of multiple sclerosisAnnals of Neurology, 1996
- The Effect of Repositioning Error on Serial Magnetic Resonance Imaging ScansArchives of Neurology, 1993