Diagnostic accuracy of hepatic proton density fat fraction measured by magnetic resonance imaging for the evaluation of liver steatosis with histology as reference standard: a meta-analysis
Authors:
- 15 March 2019
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 29 (10) , 5180-5189
Abstract
Objectives The aim of this meta-analysis was to evaluate the diagnostic accuracy of hepatic magnetic resonance imaging-proton density fat fraction (MRI-PDFF) for the assessment of liver steatosis (LS) with histology as reference standard. Methods A systematic literature search was performed to identify pertinent studies. Quality analyses were conducted by Quality Assessment of Diagnostic Accuracy Studies-2. Diagnostic data were extracted and inconsistency index was calculated for LS≥G1, LS≥G2, and LS=G3, respectively. The area under summary receiver operating characteristic curve (AUC) served as the indicator of diagnostic accuracy. The pooled sensitivity and specificity were calculated if threshold effect was absent. Results Thirteen studies containing 1100 subjects were included. There was significant threshold effect for LS≥G1. The AUCs for LS≥G1, LS≥G2, and LS=G3 were 0.98 (95% confidence interval (CI) 0.76, 1.00), 0.91 (95% CI 0.89, 0.94), and 0.92 (95% CI 0.89, 0.94), respectively. The pooled sensitivities for LS≥G2 and LS=G3 were 0.83 (95% CI 0.75, 0.88) and 0.79 (95% CI 0.63, 0.90), respectively; the pooled specificities for LS≥G2 and LS=G3 were 0.89 (95% CI 0.84, 0.92) and 0.89 (95% CI 0.84, 0.92), respectively. Conclusions MRI-PDFF has high diagnostic accuracy at detecting and grading LS with histology as reference standard, suggesting that MRI-PDFF is able to provide an accurate quantification of LS in clinical trials and patient care. Key Point • MRI-PDFF is able to provide an accurate quantification of LS in clinical trials and patient care.Keywords
Funding Information
- National Natural Science Foundation of China (81471658)
This publication has 58 references indexed in Scilit:
- QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy StudiesAnnals of Internal Medicine, 2011
- Quantitative assessment of liver fat with magnetic resonance imaging and spectroscopyJournal of Magnetic Resonance Imaging, 2011
- Percutaneous liver biopsy: patients' point of viewScandinavian Journal of Gastroenterology, 2011
- Quantification of Hepatic Steatosis with T1-independent, T2*-corrected MR Imaging with Spectral Modeling of Fat: Blinded Comparison with MR SpectroscopyRadiology, 2011
- Estimation of Hepatic Proton-Density Fat Fraction by Using MR Imaging at 3.0 TRadiology, 2011
- The diagnostic accuracy of US, CT, MRI and 1H-MRS for the evaluation of hepatic steatosis compared with liver biopsy: a meta-analysisEuropean Radiology, 2010
- Nonalcoholic fatty liver disease and liver transplantationLiver Transplantation, 2006
- Bivariate analysis of sensitivity and specificity produces informative summary measures in diagnostic reviewsJournal of Clinical Epidemiology, 2005
- Design and validation of a histological scoring system for nonalcoholic fatty liver disease†Hepatology, 2005
- Measuring inconsistency in meta-analysesBMJ, 2003