Abstract
While two-photon fluorescence microscopy is a powerful platform for the study of functional dynamics in living cells and tissues, the bulk motion inherent to these applications causes distortions. We have designed a motion tracking module based on spectral domain optical coherence tomography which compliments a laser scanning two-photon microscope with real-time corrective feedback. The module can be added to fluorescent imaging microscopes using a single dichroic and without additional contrast agents. We demonstrate that the system can track lateral displacements as large as 10 μm at 5 Hz with latency under 14 ms and propose a scheme to extend the system to 3D correction with the addition of a remote focusing module. We also propose several ways to improve the module’s performance by reducing the feedback latency. We anticipate that this design can be adapted to other imaging modalities, enabling the study of samples subject to motion artifacts at higher resolution.Keywords
Funding Information
- Division of Biological Infrastructure (1934288)
This publication has 27 references indexed in Scilit:
- Rapid 3D light-sheet microscopy with a tunable lensOptics Express, 2013
- Reduction of motion artifacts during in vivo two‐photon imaging of brain through heartbeat triggered scanningThe Journal of Physiology, 2012
- Motion correction in optical coherence tomography volumes on a per A-scan basis using orthogonal scan patternsBiomedical Optics Express, 2012
- Graphics processing unit accelerated non-uniform fast Fourier transform for ultrahigh-speed, real-time Fourier-domain OCTOptics Express, 2010
- Functional imaging of hippocampal place cells at cellular resolution during virtual navigationNature Neuroscience, 2010
- Imaging Large-Scale Neural Activity with Cellular Resolution in Awake, Mobile MiceNeuron, 2007
- Ultrahigh-resolution high-speed retinal imaging using spectral-domain optical coherence tomographyOptics Express, 2004
- Optical coherence tomographic elastography technique for measuring deformation and strain of atherosclerotic tissuesHeart, 2004
- An FFT-based technique for translation, rotation, and scale-invariant image registrationIEEE Transactions on Image Processing, 1996
- A New Approach to Linear Filtering and Prediction ProblemsJournal of Basic Engineering, 1960