Plethysmographic measurements of lung volume and airway resistance
Authors:
Open Access
- 1 February 2001
- journal article
- guideline
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 17 (2) , 302-312
Abstract
Functional residual capacity (FRC) is the only static lung volume that can be measured routinely in infants. It is important for interpreting volume-dependent pulmonary mechanics such as airway resistance or forced expiratory flows, and for defining normal lung growth. Despite requiring complex equipment, the plethysmographic method for measuring FRC is very simple to apply and, unlike the gas dilution techniques, enables repeat measures of lung volume to be obtained within a few minutes. This method has the further advantage that with suitable adaptations to the equipment, simultaneous measurements of airway resistance can also be obtained.The aim of this paper is to provide recommendations pertaining to equipment requirements, study procedures and reporting of data for plethysmographic measurements in infants. Implementation of these recommendations should help to ensure that such measurements are as accurate as possible and that meaningful comparisons can be made between data collected in different centres or with different equipment. These guidelines cover numerous aspects including terminology and definitions, equipment, data acquisition and analysis and reporting of results and also highlight areas where further research is needed before consensus can be reached.Keywords
This publication has 23 references indexed in Scilit:
- Specification for signal processing and data handling used for infant pulmonary function testing. ERS/ATS Task Force on Standards for Infant Respiratory Function Testing. European Respiratory Society/American Thoracic SocietyEuropean Respiratory Journal, 2000
- Specifications for equipment used for infant pulmonary function testingEuropean Respiratory Journal, 2000
- A simple new technique to measure the effective dead space of the face mask with a water volumeter in infantsEuropean Respiratory Journal, 1999
- Frequency dependence of specific airway resistance in a commercialized plethysmographEuropean Respiratory Journal, 1996
- Improved accuracy of the occlusion technique for assessing total respiratory compliance in infantsPediatric Pulmonology, 1987
- Airway Resistance Measurements throughout the Respiratory Cycle in InfantsRespiration, 1986
- Flow-pressure looping during plethysmography in wheezy infantsPediatric Pulmonology, 1985
- The numerical analysis of pressure‐flow curves in infancyPediatric Pulmonology, 1985
- Specific airway conductance in guinea pigs: Normal values and histamine induced fallRespiration Physiology, 1981
- On the Advantages of Specific Airway ResistancePediatric Research, 1978