Amplitude-Phase Detection for Power Converters Tied to Unbalanced Grids with Large X/R Ratios
- 13 August 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. PP (08858993) , 1
Abstract
Amplitude-phase information of the voltage/current phasor, which is the prerequisite for grid-tied converter control and protection, can change almost instantaneously in low-voltage distribution systems with small X/R ratios. However, the equivalent impedances of high-voltage power systems are usually inductive (with large X/R ratios), and the power flow of pertinent grids generates decaying DC (DDC) components with large amplitude and long duration during large disturbances. Therefore, the X/R ratios and DDC components must be fully considered in amplitude-phase detection to achieve effective converter control and protection. To this end, the main components present in the transient voltage/current of a high-voltage power system after unbalanced disturbance are first analyzed, and the general transient model is obtained by synthesizing multi-mode DDC components. Then, by resorting to waveform characteristics of different components, an amplitude-phase detection algorithm is proposed based on the multi-component parallel-detection structure. Compared to existing techniques, the detection time is reduced to half grid cycle. Finally, an iterative variable-interval integral algorithm is developed, improving the anti-noise ability of detection algorithm, and overcoming the computational burden issue. This enables the direct integration of algorithm into the converter's embedded processor. Experiment results verified the effectiveness and superiority of the proposed technique.Keywords
Funding Information
- National Natural Science Foundation of China (51707091)
- Key Laboratory of Control of Power Transmission and Conversion SJTU Ministry of Education (2018AC04)
This publication has 23 references indexed in Scilit:
- Harmonics and Decaying DC Estimation Using Volterra LMS/F AlgorithmIEEE Transactions on Industry Applications, 2017
- A New DC-Offset Removal Method for Distance-Relaying Application Using Intrinsic Time-Scale DecompositionIEEE Transactions on Power Delivery, 2017
- Grid Voltage Synchronization for Unbalanced Voltages Using the Energy OperatorIEEE Journal of Emerging and Selected Topics in Power Electronics, 2017
- DC Offset Removal Algorithm for Improving Location Estimates of Momentary FaultsIEEE Transactions on Smart Grid, 2017
- Flexible Power Regulation and Current-Limited Control of the Grid-Connected Inverter Under Unbalanced Grid Voltage FaultsIEEE Transactions on Industrial Electronics, 2017
- Development of Phasor Estimation Algorithm for P-Class PMU Suitable in Protection ApplicationsIEEE Transactions on Smart Grid, 2016
- A Quantitative Evaluation and Comparison of Harmonic Elimination Algorithms Based on Moving Average Filter and Delayed Signal Cancellation in Phase Synchronization ApplicationsJournal of Power Electronics, 2016
- A Fast Orthogonal Signal-Generation Algorithm Characterized by Noise Immunity and High Accuracy for Single-Phase GridIEEE Transactions on Power Electronics, 2015
- A Modified Empirical Mode Decomposition Filtering-Based Adaptive Phasor Estimation Algorithm for Removal of Exponentially Decaying DC OffsetIEEE Transactions on Power Delivery, 2014
- Comparative Analysis Between ROCOF and Vector Surge Relays for Distributed Generation ApplicationsIEEE Transactions on Power Delivery, 2005