Abstract
Objective: The study in patients with percutaneous left atrial appendage (LAA) occlusion investigates clinical outcomes according to the position of the Amplatzer Cardiac Plug (ACP) disc.Background: The ACP consists of a disc and an anchoring lobe. The disc is meant to cover the ostium of the LAA, but frequently retracts partially or completely into the neck of the LAA. It is not known whether a retracted disc affects outcome.Methods: Outcomes of 169 consecutive patients (age 73.1 ± 10.4 years; 76% male) with successful LAA closure were analyzed according to the position of the ACP disc: group A had complete coverage of the LAA ostium; in group B the disc prolapsed partially or completely into the LAA‐neck. Transesophageal echocardiography was performed 1‐6 months after ACP implantation. The safety endpoint was the composite of clinically significant pericardial effusion, device embolization, procedure‐related stroke/transient ischemic attack (TIA), major bleeding, or device thrombus. The efficacy endpoint was the composite of death, neurological events (ischemic and hemorrhagic stroke, TIA), or systemic embolism during follow‐up.Results: Group A comprised 76 patients (age 73.0 ± 9.9 years; 74% male) and group B 93 patients (age 73.3 ± 10.9 years; 79% male). Mean CHA2DS2‐Vasc score and HASBLED score were 4.2 ± 1.7 (group A 4.3 ± 1.6; group B 4.2 ± 1.8) and 2.9 ± 1.1 (group A 2.9 ± 1.0; group B 3.0 ± 1.2), respectively. Mean follow‐up of the study population was 13.0 ± 10.4 months. Overall, the composite safety and efficacy endpoints occurred in 20 (12%) and 6 patients (4%), respectively. There was no significant difference between groups A and B in the occurrence of the safety endpoint (13% vs. 11%, P = 0.64), or the efficacy endpoint (4% vs. 3%, P = 1.0).Conclusions: No evidence for a difference in the occurrence of the safety and efficacy endpoint was found between patients with complete vs. incomplete ACP disc coverage of the LAA ostium. The risk of repositioning attempts in case of incomplete coverage does not seem to be warranted. Current findings need further confirmation in a larger scale clinical trial.Keywords
This publication has 17 references indexed in Scilit:
- Oclusão do apêndice atrial esquerdo com o Amplatzer Cardiac Plug em pacientes com fibrilação atrialArquivos Brasileiros de Cardiologia, 2012
- The Clinical Impact of Incomplete Left Atrial Appendage Closure With the Watchman Device in Patients With Atrial FibrillationJACC, 2012
- Safety of Percutaneous Left Atrial Appendage ClosureCirculation, 2011
- Left atrial appendage closure with amplatzer cardiac plug in atrial fibrillation: Initial european experienceCatheterization and Cardiovascular Interventions, 2010
- Left Atrial Appendage ObliterationJACC: Cardiovascular Interventions, 2010
- Percutaneous Left Atrial Appendage Transcatheter Occlusion (PLAATO System) to Prevent Stroke in High-Risk Patients With Non-Rheumatic Atrial FibrillationJACC, 2005
- Cardiac anatomy revisitedJournal of Anatomy, 2004
- Transcatheter left atrial appendage occlusion with Amplatzer devices to obviate anticoagulation in patients with atrial fibrillationCatheterization and Cardiovascular Interventions, 2003
- Percutaneous Left Atrial Appendage Transcatheter Occlusion to Prevent Stroke in High-Risk Patients With Atrial FibrillationCirculation, 2002
- Appendage obliteration to reduce stroke in cardiac surgical patients with atrial fibrillationThe Annals of Thoracic Surgery, 1996