Biventricular Circulatory Support With Two Miniaturized Implantable Assist Devices
Open Access
- 13 September 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 124 (11_suppl_1) , S179-S186
Abstract
Background—Up to 30% of patients with end-stage heart failure experience biventricular failure that requires biventricular mechanical support. For these patients, only bulky extracorporeal or implantable displacement pumps or the total artificial heart have been available to date, which enables only limited quality of life for the patients. It was our goal to evaluate a method that would allow the use of 2 implantable centrifugal left ventricular assist devices as a biventricular assist system. Methods and Results—Seventeen patients have been implanted with 2 HeartWare HVAD pumps, 1 as a left ventricular assist device and 1 as a right ventricular assist device. Seventy-seven percent of the patients had idiopathic dilated or ischemic cardiomyopathy. Their age ranged from 29 to 73 years (mean 51.8±14.5 years), and 11 (64.7%) received intravenous catecholamine support preoperatively. The right ventricular assist device pump was implanted into the right ventricular free wall. The afterload of this pump was artificially increased by local reduction of the outflow graft diameter, and the effective length of its inflow cannula was reduced by the addition of two 5-mm silicon suture rings to the original HVAD implantation ring. All right ventricular assist device devices could be operated in appropriate speed ranges and delivered a flow of between 3.0 and 5.5 L/min. Thirty-day survival was 82%, and 59% of the patients could be discharged home after recovering from the operation. There was no clinically relevant hemolysis in any of the patients. Conclusions—Two HeartWare HVAD pumps can be used as a biventricular assist system. This implantable biventricular support gives the patients more comfort and mobility than usual biventricular ventricular assist devices with large and noisy displacement pumps.Keywords
This publication has 11 references indexed in Scilit:
- Evaluation of the HeartWare HVAD Centrifugal Pump for Right Ventricular Assistance in an In Vitro ModelASAIO Journal, 2011
- Right-to-left ventricular end-diastolic diameter ratio and prediction of right ventricular failure with continuous-flow left ventricular assist devicesThe Journal of Heart and Lung Transplantation, 2011
- Long-term biventricular support with the heartware implantable continuous flow pumpThe Journal of Heart and Lung Transplantation, 2010
- Second INTERMACS annual report: More than 1,000 primary left ventricular assist device implantsThe Journal of Heart and Lung Transplantation, 2010
- Advanced Heart Failure Treated with Continuous-Flow Left Ventricular Assist DeviceThe New England journal of medicine, 2009
- Extended Mechanical Circulatory Support With a Continuous-Flow Rotary Left Ventricular Assist DeviceJACC, 2009
- Tricuspid Incompetence and Geometry of the Right Ventricle as Predictors of Right Ventricular Function After Implantation of a Left Ventricular Assist DeviceThe Journal of Heart and Lung Transplantation, 2008
- Risk Score Derived from Pre-operative Data Analysis Predicts the Need for Biventricular Mechanical Circulatory SupportThe Journal of Heart and Lung Transplantation, 2008
- Biventricular assistance with the Jarvik FlowMaker: A case reportThe Journal of Thoracic and Cardiovascular Surgery, 2004
- A versatile intracorporeal ventricular assist device based on the Thoratec VAD systemThe Annals of Thoracic Surgery, 2001