Molecular epidemiological investigation of an outbreak of Pseudomonas aeruginosa infection in an SCT unit
Authors:
- 13 October 2008
- journal article
- research article
- Published by Springer Nature in Bone Marrow Transplantation
- Vol. 43 (4) , 335-338
Abstract
From May to October 2006, six severe Pseudomonas aeruginosa infections were diagnosed in patients undergoing SCT in the SCT unit of the Careggi hospital (Florence, Italy). Four of the infected patients were treated consecutively in the same room (room N). On the hypothesis of a possible environmental source of infection, samples were collected from different sites that had potential for cross-contamination throughout the SCT unit, including the electrolytic chloroxidant disinfectant used for hand washing (Irgasan) and the disinfectant used for facilities cleaning. Four of the environmental samples were positive for P. aeruginosa: three Irgansan soap samples and a tap swab sample from the staff cleaning and dressing room. The AFLP (amplified fragment length polymorphism) typing method employed to evaluate strain clonality showed that the isolates from the patients who had shared the same room and an isolate from Irgasan soap had a significant molecular similarity (dice index higher than 0.93). After adequate control measures, no subsequent environmental sample proved positive for P. aeruginosa. These data strongly support the hypothesis of the clonal origin of the infective strains and suggest an environmental source of infection. The AFLP method was fast enough to allow a ‘real-time’ monitoring of the outbreak, permitting additional preventive measures.Keywords
This publication has 13 references indexed in Scilit:
- Invasive Pseudomonas aeruginosa infections: high rate of recurrence and mortality after hematopoietic cell transplantationBone Marrow Transplantation, 2007
- Presumed pseudobacteremia outbreak resulting from contamination of proportional disinfectant dispenserEuropean Journal of Clinical Microbiology & Infectious Diseases, 2007
- Pseudomonas aeruginosa and Pseudomonas putida outbreak associated with contaminated water outlets in an oncohaematology paediatric unitJournal of Hospital Infection, 2007
- Pseudomonas aeruginosaSepsis in Stem Cell Transplantation PatientsInfection Control & Hospital Epidemiology, 2006
- Ecology of Pseudomonas aeruginosa in the intensive care unit and the evolving role of water outlets as a reservoir of the organismAmerican Journal of Infection Control, 2005
- Outbreaks of infectious diseases in stem cell transplant units: a silent cause of death for patients and transplant programmesBone Marrow Transplantation, 2004
- Guideline for Hand Hygiene in Health-Care Settings: Recommendations of the Healthcare Infection Control Practices Advisory Committee and the HICPAC/SHEA/APIC/IDSA Hand Hygiene Task ForceInfection Control & Hospital Epidemiology, 2002
- An Outbreak of Multidrug-ResistantPseudomonas AeruginosaAssociated with Increased Risk of Patient Death in an Intensive Care UnitInfection Control & Hospital Epidemiology, 2002
- AFLP: a new technique for DNA fingerprintingNucleic Acids Research, 1995
- Serratia marcescansContamination of Antiseptic Soap Containing Triclosan: Implications for Nosocomial InfectionInfection Control, 1984