Accurate and Robust Locomotion Mode Recognition Using High-Density EMG Recordings from a Single Muscle Group
Authors:
- 11 July 2022
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2022, 686-689
Abstract
Existing methods for human locomotion mode recognition often rely on using multiple bipolar electrode sensors on multiple muscle groups to accurately identify underlying motor activities. To avoid this complex setup and facilitate the translation of this technology, we introduce a single grid of high-density surface electromyography (HDsEMG) electrodes mounted on a single location (above the rectus femoris) to classify six locomotion modes in human walking. By employing a neural network, the trained model achieved average recognition accuracy of 97.7% with 160ms latency, significantly better than the model trained with one bipolar electrode pair placed on the same muscle (71.4% accuracy). To further exploit the spatial and temporal information of HDsEMG, we applied data augmentation to generate artificial data from simulated displaced electrodes, aiming to counteract the influence of electrode shifts. By employing a convolutional neural network with the enhanced dataset, the updated model was not strongly affected by electrode misplacement (93.9% accuracy) while models trained by bipolar electrode data were significantly disrupted by electrode shifts (29.4% accuracy). Findings suggest HDsEMG could be a valuable resource for mapping gait with fewer sensor locations and greater robustness. Results offer future promise for real-time control of assistive technology such as exoskeletons.Keywords
Funding Information
- EPSRC (EP/T020970/1)
This publication has 7 references indexed in Scilit:
- Advances and Disturbances in sEMG-Based Intentions and Movements Recognition: A ReviewIEEE Sensors Journal, 2021
- Forearm High-Density Electromyography Data Visualization and Classification with Machine Learning for Hand Prosthesis Control2020
- Tutorial. Surface EMG detection in space and time: Best practicesJournal of Electromyography and Kinesiology, 2019
- Fusion of Bilateral Lower-Limb Neuromechanical Signals Improves Prediction of Locomotor ActivitiesFrontiers in Robotics and AI, 2018
- Electrode Density Affects the Robustness of Myoelectric Pattern Recognition System With and Without Electrode ShiftIEEE Journal of Biomedical and Health Informatics, 2018
- Continuous Locomotion-Mode Identification for Prosthetic Legs Based on Neuromuscular–Mechanical FusionIEEE Transactions on Biomedical Engineering, 2011
- A robust, real-time control scheme for multifunction myoelectric controlIEEE Transactions on Biomedical Engineering, 2003