Comparison of Four Techniques for the Detection of Clostridium Perfringens Type D Epsilon Toxin in Intestinal Contents and other Body Fluids of Sheep and Goats
Authors:
Open Access
- 1 March 2003
- journal article
- research article
- Published by SAGE Publications in Journal of Veterinary Diagnostic Investigation
- Vol. 15 (2) , 94-99
Abstract
Polyclonal capture enzyme-linked immunosorbent assay (PC-ELISA), monoclonal capture ELISA (MC-ELISA), mouse neutralization test (MNT), and counterimmunoelectrophoresis (CIEP), were compared for their ability to detect epsilon toxin in intestinal contents and body fluids of sheep and goats. When used to evaluate intestinal contents of sheep artificially spiked with epsilon prototoxin, PC-ELISA detected 0.075 mouse lethal dose (MLD)50/ml, whereas the MNT, MC-ELISA, and CIEP detected 6, 25, and 50 MLD50/ml, respectively. Amounts of epsilon toxin detected by PC-ELISA, MC-ELISA, MNT, and CIEP in sheep pericardial fluid artificially spiked with epsilon prototoxin were 0.075, 0.75, 6, and 200 MLD50/ml, respectively. For assaying epsilon toxin in aqueous humor, PC-ELISA and MC-ELISA detected 0.075 MLD50/ml, whereas CIEP detected 200 MLD50/ml (MNT was not evaluated). When 51 samples of intestinal contents of sheep and goats (32 positive and 19 negative to MNT) were analyzed by the other 3 techniques, the relative sensitivity of PC-ELISA, MC-ELISA, and CIEP was 93.75, 84.37, and 37.50%, respectively. The specificity of PC-ELISA, MC-ELISA, and CIEP was 31.57, 57.89, and 84.21%, respectively. The absolute sensitivity of PC-ELISA, MC-ELISA, CIEP, and MNT was 90.90, 69.69, 15.15, and 54.54%. The absolute specificity of the 4 techniques was 100%. These results show that there is a marked inconsistency among techniques routinely used to detect Clostridium perfringens epsilon toxin. Until more consistent results are achieved, the diagnosis of enterotoxemia should not only be based solely on epsilon toxin detection, but also on clinical and pathological data.Keywords
This publication has 11 references indexed in Scilit:
- Effects of Intravenous Injection of Clostridium perfringens Type D Epsilon Toxin in CalvesJournal of Comparative Pathology, 2002
- Experimental Clostridium perfringens Type D Enterotoxemia in GoatsVeterinary Pathology, 1998
- Enterotoxaemia in goatsVeterinary Research Communications, 1996
- Development of double sandwich ELISA for Clostridium perfringens beta and epsilon toxinsVeterinary Microbiology, 1992
- Enzyme-linked immunosorbent assay for rapid detection of toxins fromClostridium perfringensFEMS Microbiology Letters, 1991
- Comparison of counter immunoelectrophoresis with mouse protection assay in the detection of epsilon toxin in the intestinal contents of goatsAustralian Veterinary Journal, 1989
- An enzyme labelled immunosorbent assay for measuringClostridium perfringensepsilon toxin in gut contentsNew Zealand Veterinary Journal, 1985
- Pulpy kidney disease and its diagnosis by histological examinationVeterinary Record, 1978
- Application of the Indirect Enzyme-Labeled Antibody Microtest to the Detection and Surveillance of Animal DiseasesThe Journal of Infectious Diseases, 1977
- Enterotoxæmia of sheep: Clostridium welchii type D in the alimentary tract of normal animalsThe Journal of Pathology and Bacteriology, 1952