Determining the Fat Acidity of Rough Rice by Near‐Infrared Reflectance Spectroscopy
Authors:
- Wang‐Sheng LiWLWang‐Sheng Li
- Jai‐Tsung ShawJSJai‐Tsung Shaw
- 15 September 1997
- journal article
- Published by Wiley in Cereal Chemistry
- Vol. 74 (5) , 556-560
Abstract
Near‐infrared reflectance spectroscopy (NIRS) was used to develop calibration curves for determining the fat acidity of whole‐kernel and ground rough rice with 13% moisture content at 25°C. Partial‐leastsquares regression (PLSR) uses the optimal calibration curve for wholekernel rough rice to measure the coefficient of determination (r2) of validation and standard error of prediction (SEP) of 0.87 and 0.83 mg of KOH/100 g of dry matter, respectively. However, the optimal calibration curve for ground rough rice has a higher r2 of validation and lower SEP of 0.94 and 0.73 mg of KOH/100 g of dry matter, respectively. From 10 to 40°C, the temperature effect causes an increase of 0.24 mg of KOH/100 g of dry matter/°C in the predicted fat acidity of whole‐kernel rough rice.Keywords
This publication has 1 reference indexed in Scilit:
- Near-Infrared Spectra of Fatty Acids and Some Related SubstancesAnalytical Chemistry, 1956