Detection of internal combustion engine knock using time-frequency distributions
Authors:
- 30 December 2002
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 360-363
Abstract
Detection methods employed in current knock control systems for spark ignition engines use a measurement of engine block vibration tuned to one or more resonance frequencies to extract knock-related information from the engine structural vibration. These techniques suffer from poor signal-to-noise ratio at high engine speed, due to background vibration. This paper presents an improved knock detection scheme capable of tracking variations in the knock resonance frequencies. Experimental results obtained on a single-cylinder research engine confirm the validity of the method.Keywords
This publication has 4 references indexed in Scilit:
- A methodology for detection and classification of some underwater acoustic signals using time-frequency analysis techniquesIEEE Transactions on Acoustics, Speech, and Signal Processing, 1990
- Time-frequency distributions-a reviewProceedings of the IEEE, 1989
- Improved time-frequency representation of multicomponent signals using exponential kernelsIEEE Transactions on Acoustics, Speech, and Signal Processing, 1989
- An efficient real-time implementation of the Wigner-Ville distributionIEEE Transactions on Acoustics, Speech, and Signal Processing, 1987