Fibrin Glue and Polyglycolic Acid Nonwoven Fabric as a Biocompatible Dural Substitute
Authors:
- Shunsuke TerasakaSTShunsuke Terasaka
- Yoshinobu IwasakiYIYoshinobu Iwasaki
- Noriko ShinyaNSNoriko Shinya
- Takanori UchidaTUTakanori Uchida
- 1 February 2006
- journal article
- research article
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 58, ONS134-134
Abstract
A novel biocompatible dural substitute created using fibrin glue and polyglycolic acid nonwoven fabric was examined for closing ability and histology. A rabbit skin model of dural defect was repaired using fibrin glue-covered polyglycolic acid fabric without suture and subjected to a water leakage test to investigate closing ability. In addition, the dural defects created on 12 hemispheres in 6 beagle dogs were repaired with the dural substitute and subjected to macroscopic and histological examination of the dural substitute and adjacent tissue 1 and 2 months later. The dural substitute showed a breaking pressure of 109.9 +/- 37.1 mmHg. Macroscopically, no cases of excessive granulation, infection, or liquorrhea, either on the dural substitute or surrounding tissue, were observed. Histology indicated favorable tissue replacement of the dural substitute with collagenous fiber, although slight foreign body reaction was associated with its absorption. There was no evidence for adhesion to the brain surface or influence on nerve cells. Dural substitute created using fibrin glue and polyglycolic acid fabric is advantageous in that it exerts excellent closing ability without requiring suture and can replace biological tissue without causing incompatibility.Keywords
This publication has 14 references indexed in Scilit:
- Comparison of Deep Wound Infection Rates Using a Synthetic Dural Substitute (Neuro-Patch) or Pericranium Graft for Dural Closure: A Clinical Review of 1 YearNeurosurgery, 2004
- Propionibacterium as a Cause of Postneurosurgical Infection in Patients with Dural Allografts: Report of Three CasesNeurosurgery, 1999
- Efficacy and biocompatibility of a photopolymerized, synthetic, absorbable hydrogel as a dural sealant in a canine craniotomy modelJournal of Neurosurgery, 1998
- Ovine pericardium as a new material for duraplastyJournal of Neurosurgery, 1996
- A synthetic dural prosthesis constructed from hydroxyethylmethacrylate hydrogelsJournal of Neurosurgery, 1995
- Immune response in hosts with cadaveric dural graftsJournal of Neurosurgery, 1994
- Experimental evaluation of bilayered human collagen as a dural substituteJournal of Neurosurgery, 1993
- Vicryl (polyglactin 910) mesh as a dural substitute in the presence of pia arachnoid injuryJournal of Neurosurgery, 1989
- Study and clinical application of a porcine biomembrane for the repair of dural defectsJournal of Neurosurgery, 1988
- Vicryl (polyglactin 910) mesh as a dural substituteJournal of Neurosurgery, 1985