Experimental Validation of CFD Predictions for Internal Duct Airflow and Thermal Behaviour in a High-Speed Train Supply Duct Prototype: A Preliminary Stage Towards Carbody Integrated HVAC Testing
Authors:
- Fauzun FauzunFFFauzun Fauzun
- Muhammad Arkan Febian HermadaMHMuhammad Arkan Febian Hermada
- Fakhreza AreliFAFakhreza Areli
- Arsyadani Tsalisul IlhamAIArsyadani Tsalisul Ilham
- Fariz Galang Nusantara Putra SetiawanFSFariz Galang Nusantara Putra Setiawan
- Samsul Ma’AripSMSamsul Ma’Arip
- Cahyo Wibi YogiswaraCYCahyo Wibi Yogiswara
Open Access
Abstract
Unlike many previous high-speed train Heating, Ventilation, and Air Conditioning (HVAC) studies that combined numerical and experimental analyses within the cabin, this study evaluates the supply duct independently, offering a more targeted assessment of internal duct airflow and thermal performance. The research comprised two numerical stages and an experimental validation. The first stage evaluated four ducting geometry variations and identified the ducting system arrangement of 20 supply diffusers with a 45° air grille blocking angle as optimal for the Kereta Cepat Merah Putih (KCMP) case, keeping air velocity within the thermal comfort range for all simulated passengers. This geometry was then manufactured as a full-scale prototype and assessed in a second numerical stage against experimental measurements. The air velocity yielded a mean absolute deviation (MAD) of 0.57 m/s and a relative mean deviation (RMD) of 34.22%, while the air temperature showed an MAD of 2.13 °C and an RMD of 8.16% at duct planes, and 0.80 °C and 3.06% at duct outlets. These results demonstrate that the proposed approach of testing the supply duct independently of the cabin is able to capture the general internal duct airflow trends, even though, particularly for the temperature parameters, a large temperature discrepancy occurs at downstream locations traced to three factors: uncontrolled ambient thermal conditions in a large-scale indoor facility, simplified thermal boundary conditions in the simulation, and additional uncertainty from the non-standardised temperature measurement method. Nonetheless, it offers a promising preliminary reference for HVAC system development, prior to integrated carbody testing, although further method refinements are still required to strengthen the reliability of this approach.Keywords
Funding Information
- Ministry of Education, Culture, Research and Technology of Indonesia (142/E1/KS.00.00/2024)
- Ministry of Higher Education, Science, and Technology (87/SPK/C.C4/PPK.DHK/IX/2026)
This publication has 33 references indexed in Scilit:
- Flow characteristics and structural optimization of uniform air supply duct systems in subway stations for improving airflow uniformityBuilding and Environment, 2025
- The airflow characteristics and thermal comfort evaluation in high-speed train cabin with mixing ventilation: An experimental and numerical studyBuilding and Environment, 2024
- Study of the convection heat transfer law and temperature prediction of the duct in high-temperature tunnelsCase Studies in Thermal Engineering, 2022
- Evaluation of different air distribution systems in a commercial airliner cabin in terms of comfort and COVID-19 infection riskBuilding and Environment, 2021
- Influencing factors in the simulation of airflow and particle transportation in aircraft cabins by CFDBuilding and Environment, 2021
- Ventilation effectiveness of uniform and non-uniform perforated duct diffusers at office roomBuilding and Environment, 2021
- Experimental and numerical investigation of TVOC concentrations and ventilation dilution in enclosed train cabinBuilding Simulation, 2021
- Impact of maritime logistics on archipelagic economic development in eastern IndonesiaThe Asian Journal of Shipping and Logistics, 2021
- Multi-objective optimization for designing of high-speed train cabin ventilation system using particle swarm optimization and multi-fidelity KrigingBuilding and Environment, 2019
- Air diffusion performance index (ADPI) of overhead-air-distribution at low cooling loadsEnergy and Buildings, 2017