Towards a metamaterial approach for fast timing in PET: experimental proof-of-concept
Open Access
- 1 September 2019
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (18) , 185018
Abstract
Achieving fast timing in positron emission tomography (PET) at the level of few tens of picoseconds of picoseconds is limited by the photon emission rate of existent materials with standard scintillation mechanisms. This has led to consider quantum confined excitonic sub-1 ns emission in semiconductors as a viable solution to enhance the amount of fast-emitted photons produced per gamma event. However the introduction of nanocrystals and nanostructures into the domain of radiation detectors is a challenging problem. In order to move forward along this line, the standard bulk detector geometry and readout should be updated to allow for the implementation of new materials and within others, compensate for some of their intrinsic limitations. In this paper we will cover two study cases in which a fast emitter is combined with state-of-the-art scintillators in a sampling geometry designed to provide better timing for a fraction of the 511 keV events. For this test, we use a fast plastic scintillator BC-422 able to deliver a detector time resolution (DTR) of 25 ps FWHM (equivalent coincidence time resolution CTR of 35 ps) and we combined it with LYSO or BGO 200 m thick plates building a sampling pixel composed by two active scintillating materials. We develop a new proof of concept readout that allows for the identification of different types of events, carrying standard or improved timing information. Results are showing a DTR of 67 ps FWHM (equivalent to a CTR of 95 ps) for one third of the events depositing 511 keV in the BGO + BC-422 mm3 sampling pixel. The other two third of the 511 keV events perform like standard bulk 3 mm long BGO crystals with a time resolution of around 117 ps (equivalent to a CTR of 165 ps). For the case of LYSO + BC-422 sampling pixel, shared 511 keV events reach a DTR of 39 ps (CTR of 55 ps) in comparison to 57 ps (CTR of 83 ps) for 511 keV events fully contained in LYSO of the same size. This work is a step forward in the integration of fast semiconductor nanocrystals and nanostructures with present detector technologies.Keywords
Funding Information
- TICAL ERC (338953)
- FAST Cost Action (TD1401)
- ASCIMAT (690599)
This publication has 14 references indexed in Scilit:
- High-frequency SiPM readout advances measured coincidence time resolution limits in TOF-PETPhysics in Medicine & Biology, 2019
- InGaN/GaN Structures: Effect of the Quantum Well Number on the Cathodoluminescent PropertiesPhysica Status Solidi (b), 2017
- Pushing the Limits in Time-of-Flight PET ImagingIEEE Transactions on Radiation and Plasma Medical Sciences, 2017
- State of the art timing in TOF-PET detectors with LuAG, GAGG and L(Y)SO scintillators of various sizes coupled to FBK-SiPMsJournal of Instrumentation, 2016
- Measurement of intrinsic rise times for various L(Y)SO and LuAG scintillators with a general study of prompt photons to achieve 10 ps in TOF-PETPhysics in Medicine & Biology, 2016
- Modelling energy deposition in nanoscintillators to predict the efficiency of the X-ray-induced photodynamic effectNanoscale, 2015
- Continuous-wave biexciton lasing at room temperature using solution-processed quantum wellsNature Nanotechnology, 2014
- Multicarrier Interactions in Semiconductor Nanocrystals in Relation to the Phenomena of Auger Recombination and Carrier MultiplicationAnnual Review of Condensed Matter Physics, 2014
- Response of Semiconductor Nanocrystals to Extremely Energetic ExcitationNano Letters, 2013
- Auger relaxation processes in semiconductor nanocrystals and quantum wellsJournal of Luminescence, 1996