Colorectal Polyps: Detection with Low-Dose Multi–Detector Row Helical CT Colonography versus Two Sequential Colonoscopies
Authors:
- Riccardo IannacconeRIRiccardo Iannaccone
- Carlo CatalanoCCCarlo Catalano
- Filippo MangiapaneFMFilippo Mangiapane
- Takamichi MurakamiTMTakamichi Murakami
- Antonietta LamazzaALAntonietta Lamazza
- Enrico FioriEFEnrico Fiori
- Alberto SchillaciASAlberto Schillaci
- Daniele MarinDMDaniele Marin
- Italo NofroniINItalo Nofroni
- Masatoshi HoriMHMasatoshi Hori
- Roberto PassarielloRPRoberto Passariello
- 1 December 2005
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 237 (3) , 927-937
Abstract
PURPOSE: To prospectively evaluate the diagnostic accuracy of low-radiation-dose computed tomographic (CT) colonography for detection of colorectal polyps by using two sequential colonoscopies, with the second colonoscopy as the reference standard.MATERIALS AND METHODS: The study was local ethics committee approved, and all patients gave written informed consent. Colonographic images were acquired by using a low-dose multi–detector row CT protocol (effective milliampere-second setting, 10 mAs). Three observers interpreted the CT colonographic data separately and independently by using a two-dimensional technique. Initial conventional colonoscopy was performed by an endoscopist unaware of the CT colonographic findings. Second colonoscopy performed within 2 weeks by a colonoscopist aware of both the CT colonographic and the initial colonoscopic findings served as the reference standard. The sensitivities of CT colonography and initial colonoscopy were calculated on a per-polyp and a per-patient basis. Specificities and positive and negative predictive values also were calculated on a per-patient basis.RESULTS: Eighty-eight patients underwent CT colonography and initial conventional colonoscopy on the same day. Per-polyp sensitivities were 62% and 83% for CT colonography and initial colonoscopy, respectively. Sensitivities for detection of polyps 6 mm in diameter or larger were 86% and 84% for CT colonography and initial colonoscopy, respectively. Initial colonoscopy failed to depict 16 polyps, six of which were correctly detected with CT colonography. For identification of patients with polyps 6 mm in diameter or larger, CT colonography and initial colonoscopy, respectively, had sensitivities of 84% and 90%, specificities of 82% and 100%, positive predictive values of 70% and 100%, and negative predictive values of 91% and 95%.CONCLUSION: Low-dose CT colonography compares favorably with colonoscopy for detection of colorectal polyps 6 mm in diameter or larger, with markedly decreased performance for detection of polyps 5 mm in diameter or smaller.© RSNA, 2005Keywords
This publication has 45 references indexed in Scilit:
- Computed tomographic colonography compared with colonoscopy in patients at increased risk for colorectal cancerGastroenterology, 2004
- Colorectal Polyps and Cancers in Asymptomatic Average-Risk Patients: Evaluation with CT ColonographyRadiology, 2004
- Computed Tomographic Virtual Colonoscopy to Screen for Colorectal Neoplasia in Asymptomatic AdultsNew England Journal of Medicine, 2003
- Computerized tomographic colonography: performance evaluation in a retrospective multicenter setting1 1Vital Images Inc. has supported research at UCLA (to D. S. K. L., J. A. B., and E. G. M.). Monex provided support (to M. M.). GE Medical Systems provided software license and research support (to C. D. J., J. A. B., and A. H. D.). Voxar, Inc. produces products that compete with products listed in this paper (to M. A. B.).The study design was approved by the National Cancer Institute Cancer Therapy Evaluation Program. Computerized tomographic colonography examinations for American College of Radiology Imaging Network Protocol A6656 were submitted by E. G. McFarland, Mallinckrodt Institute of Radiology, St. Louis, Missouri; M. Zalis, Massachusetts General Hospital, Boston, Massachusetts; C. D. Johnson, Mayo Clinic, Rochester, Minnesota; M. Macari, New York University, New York, New York; D. Lu, University of California, Los Angeles, California; A. H. Dachman, University of Chicago, Chicago, Illinois; M. Morrin, Beth Israel/Deaconess Hospitals, Boston, Massachusetts; and J. Yee, Veterans Administration Hospital, San Francisco, California. Workstations for performing computerized tomographic colonography interpretations were loaned to the American College of Radiology (ACR) by General Electric, Vital Images, and the Mayo Clinic. Each provided technical support for installation at the ACR. Computerized tomographic colonography examinations were removed and workstations returned after the study interpretations were completed.Gastroenterology, 2003
- Virtual colonoscopy using oral contrast compared with colonoscopy for the detection of patients with colorectal polypsGastroenterology, 2003
- Colorectal Neoplasia: Performance Characteristics of CT Colonography for Detection in 300 PatientsRadiology, 2001
- Optimization of CT Colonography Technique: Prospective Trial in 180 PatientsRadiology, 2000
- A Comparison of Virtual and Conventional Colonoscopy for the Detection of Colorectal PolypsNew England Journal of Medicine, 1999
- Colonoscopic miss rates of adenomas determined by back-to-back colonoscopiesGastroenterology, 1997
- Prospective Study of the Frequency and Size Distribution of Polyps Missed by ColonoscopyJNCI: Journal of the National Cancer Institute, 1990