Digital Accuracy of Closed-Tray Implant Impressions: Influence of Polyvinyl Siloxane Viscosity and Subgingival Posterior Implant Angulation
Open Access
- 12 September 2025
- journal article
- research article
- Published by MDPI AG in Dentistry Journal
- Vol. 13 (9) , 421
Abstract
Objectives: To assess the impact of PVS impression material viscosity and implant angulation on the three-dimensional accuracy of implant casts in a partially edentulous situation using the closed-tray technique. Materials and Methods: Three epoxy resin mandibular partially edentulous models (Kennedy Class I) were fabricated, each with four implant analogues placed at teeth positions 35, 37, 45, and 47. The anterior analogues were positioned parallel (0), while the posterior analogues were placed at different angulations: Group 1, 30° mesiodistal; Group 2, 20° mesiodistal; Group 3, 20° buccolingual. All analogues were placed 2 mm subgingivally. Closed-tray impressions (n = 8 per subgroup) were made using either heavy + light body PVS or monophase PVS. Resulting stone casts were scanned, and STL files were processed and analyzed using reverse engineering software (Geomagic Control X). Three-dimensional deviations (root mean square, RMS) between reference and test models were calculated by superimposition and best-fit algorithm. Results: With monophase PVS, implant angulation significantly influenced cast accuracy (p < 0.001). The 30° MD group exhibited the highest deviation (96 ± 7 µm), followed by the 20° BL group (81 ± 6 µm), then the 20° MD group (75 ± 6 µm). In contrast, no statistically significant difference in accuracy was observed among angulation groups when using heavy + light body PVS (77 ± 3 µm, 82 ± 13 µm, and 79 ± 8 µm for 30° MD, 20° BL, and 20° MD, respectively; p = 0.550). Conclusions: Both monophase and heavy + light body PVS impression materials produced clinically acceptable accuracy for closed-tray implant impressions. However, the heavy + light body PVS demonstrated greater consistency across various implant angulations and is recommended for multiple angulated subgingival posterior implants when using the closed-tray technique.Keywords
This publication has 49 references indexed in Scilit:
- Comparative analysis of dimensional changes in autoclavable polyvinyl siloxane (PVS) impressions under various Sterilization/Disinfection Protocols: A randomized controlled trialThe Saudi Dental Journal, 2024
- Accuracy of impressions for multiple implants: A comparative study of digital and conventional techniquesThe Journal of Prosthetic Dentistry, 2022
- Accuracy of full-arch digitalization for partially edentulous jaws — a laboratory study on basis of coordinate-based data analysisClinical Oral Investigations, 2022
- Assessment of impression material accuracy in complete-arch restorations on four implantsThe Journal of Prosthetic Dentistry, 2021
- Can transfer type and implant angulation affect impression accuracy? A 3D in vitro evaluationOdontology, 2021
- Changes in hardness of addition-polymerizing silicone-resilient denture liners after storage in artificial salivaThe Journal of Prosthetic Dentistry, 2019
- Effects of Implant Angulation and Impression Coping Type on the Dimensional Accuracy of ImpressionsImplant Dentistry, 2015
- Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles: A pilot studyThe Journal of Prosthetic Dentistry, 2014
- The influence of implant placement depth and impression material on the stability of an open tray impression copingThe Journal of Prosthetic Dentistry, 2012
- Accuracy of two impression techniques with angulated implantsThe Journal of Prosthetic Dentistry, 2007