Aptamer-antibody sandwich immunosensor for electrochemical detection of FT4
- 24 January 2025
- journal article
- research article
- Published by Springer Nature in Microchimica Acta
- Vol. 192 (2) , 1-10
Abstract
An aptamer-antibody sandwich electrochemical immunosensor was studied. Fe3O4/MWCNTs-COOH/Nafion was modified and fixed on a glassy carbon electrode to amplify electrical signals. The antibody was coupled with AuNPs to form conjugates. It captures the target free thyroxine (FT4) and forms antibody-AuNPs/FT4 macromolecular complexes. The complex is then captured by the aptamer on the glassy carbon electrode and detected by the electrochemical workstation using differential pulse voltammetry (DPV). Under the best conditions, the prepared sensor showed a linear relationship in the concentration range 0.1 to 105 pg/mL and the detection limit (LOD) was 0.04 pg/mL. The sensor can enhance the adsorption capacity of target FT4 and detect FT4 stably and with high selectivity. The aptamers and antibodies are free from additional modifications. In addition, the high recovery of the proposed sensor was verified by testing the human serum samples. The immunosensor has the advantages of simple operation, rapid recognition process, and short response time. These results indicate that the immunosensor is expected to achieve rapid and effective detection of FT4 in early pregnancy and evaluate thyroid function in the future. The research ideas of this work will also be applicable to the detection of other small molecules and provide ideas for the detection of other substances. Graphical AbstractKeywords
Funding Information
- the S & T Program of Hebei (No. 22567607H)
- Hebei Research Center of Pharmaceutical and Chemical Engineering (No.225676121H)
- the Military Logistics open scientific research project (No.CLB21C009)
- the Key R&D Program of Hebei Province (No. 21377786D)
This publication has 39 references indexed in Scilit:
- Binding the gap between experiments, statistics, and method comparison: A tutorial for computing limits of detection and quantification in univariate calibration for complex samplesAnalytica Chimica Acta, 2022
- A MoS2@Ti3C2Tx MXene hybrid-based electrochemical aptasensor (MEA) for sensitive and rapid detection of ThyroxineBioelectrochemistry, 2021
- Global epidemiology of thyroid disorders2020
- Ultrasensitive enzyme-free electrochemical immunoassay for free thyroxine based on three dimensionally ordered macroporous chitosan–Au nanoparticles hybrid filmBiosensors and Bioelectronics, 2014
- Electrochemical immunoassay for thyroxine detection using cascade catalysis as signal amplified enhancer and multi-functionalized magnetic graphene sphere as signal tagAnalytica Chimica Acta, 2013
- Thyroid disease in pregnancyBest Practice & Research Clinical Endocrinology & Metabolism, 2011
- Chemiluminescent immunoassay of thyroxine enhanced by microchip electrophoresisAnalytical Biochemistry, 2010
- Radioimmunoassay of free thyroxine (T4) using 125I-labeled T4-IgG complex with very large molecular weightClinica Chimica Acta, 1996
- A new radioimmunoassay of free thyroxine using 125I-labelled thyroxine—protein complex uninfluenced by albumin and thyroxine-binding globulinClinica Chimica Acta, 1987
- Free thyroxine by solid phase radioimmunoassay: improvement in the laboratory diagnosis of thyroid status in severely ill patientsClinica Chimica Acta, 1982