Minimizing magnetic fields for precision experiments
- 18 June 2015
- journal article
- conference paper
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 117 (23) , 233903
Abstract
An increasing number of measurements in fundamental and applied physics rely on magnetically shielded environments with sub nano-Tesla residual magnetic fields. State of the art magnetically shielded rooms (MSRs) consist of up to seven layers of high permeability materials in combination with highly conductive shields. Proper magnetic equilibration is crucial to obtain such low magnetic fields with small gradients in any MSR. Here, we report on a scheme to magnetically equilibrate MSRs with a 10 times reduced duration of the magnetic equilibration sequence and a significantly lower magnetic field with improved homogeneity. For the search of the neutron's electric dipole moment, our finding corresponds to a 40% improvement of the statistical reach of the measurement. However, this versatile procedure can improve the performance of any MSR for any application.Keywords
All Related Versions
Funding Information
- Deutsche Forschungsgemeinschaft
This publication has 8 references indexed in Scilit:
- A large-scale magnetic shield with 106 damping at millihertz frequenciesJournal of Applied Physics, 2015
- A magnetically shielded room with ultra low residual field and gradientReview of Scientific Instruments, 2014
- Measures to reduce the residual field and field gradient inside a magnetically shielded room by a factor of more than 10Metrology and Measurement Systems, 2013
- A next generation measurement of the electric dipole moment of the neutron at the FRM II2012
- NMR at very low fieldsMagnetic Resonance Imaging, 2010
- Influence of demagnetization coil configuration on residual field in an extremely magnetically shielded room: Model and measurementsJournal of Applied Physics, 2008
- Demagnetization of magnetically shielded roomsReview of Scientific Instruments, 2007
- Improved Experimental Limit on the Electric Dipole Moment of the NeutronPhysical Review Letters, 2006