Energy performance analysis of multi-chiller cooling systems for data centers concerning progressive loading throughout the lifecycle under typical climates
Open Access
- 29 August 2024
- journal article
- research article
- Published by Springer Nature in Building Simulation
- Vol. 17 (10) , 1693-1708
Abstract
The increasing demand for cooling energy in data centers has become a global concern. Existing studies lack a comprehensive analysis of the energy performance of widely used multi-chiller cooling systems in air-cooled data centers throughout their lifecycle, especially concerning progressive loading. To bridge this gap, this study conducts a thorough assessment of the energy performance of multi-chiller cooling systems throughout the entire lifecycle. Additionally, the impact of climate conditions on the energy efficiency of the cooling systems is analyzed, considering design variations for typical climates. Multi-chiller cooling system models are developed using the test data of cooling equipment and typical control algorithms. The energy performance of the cooling system is thoroughly analyzed under full-range cooling loads and climate conditions. Results show that free cooling time could differ up to 1442 hours at different part load ratios in the same location. Furthermore, the cooling system’s coefficient of performance (COP) varies significantly, by up to 6, at different part load ratios, corresponding to a difference in power usage effectiveness (PUE) up to 0.14. Notably, the average cooling system COP throughout the lifecycle loading is found to be only 11.7, 2.9 lower than the design system COP.Keywords
This publication has 30 references indexed in Scilit:
- Hot spot temperature prediction and operating parameter estimation of racks in data center using machine learning algorithms based on simulation dataBuilding Simulation, 2023
- Performance analysis and optimization of free cooling strategies for a liquid-cooled data centerBuilding Simulation, 2023
- An improved particle swarm optimization algorithm for the optimization and group control of water-side free cooling using cooling towersBuilding and Environment, 2020
- A Review on efficient thermal management of air- and liquid-cooled data centers: From chip to the cooling systemApplied Energy, 2017
- Cooling Systems in Data Centers: State of Art and Emerging TechnologiesEnergy Procedia, 2015
- Renewable energy system optimization of low/zero energy buildings using single-objective and multi-objective optimization methodsEnergy and Buildings, 2015
- Energy saving potential of various air-side economizers in a modular data centerApplied Energy, 2015
- Simplified server model to simulate data center cooling energy consumptionEnergy and Buildings, 2015
- Energy Efficient Thermal Management of Data Centers2012
- Simplified model for indirect-contact evaporative cooling-tower behaviourApplied Energy, 2004