Cervical nerve root avulsion in brachial plexus injuries: magnetic resonance imaging classification and comparison with myelography and computerized tomography myelography
Authors:
- Kazuteru DoiKDKazuteru Doi
- Ken OtsukaKOKen Otsuka
- Yukinori OkamotoYOYukinori Okamoto
- Hiroshi FujiiHFHiroshi Fujii
- Yasunori HattoriYHYasunori Hattori
- Amresh S. BaliarsingABAmresh S. Baliarsing
- 1 April 2002
- journal article
- research article
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 96 (3) , 277-284
Abstract
Object. The authors describe a new magnetic resonance (MR) imaging technique to demonstrate the status of the cervical nerve roots involved in brachial plexus injury. They discuss the accuracy and reproducibility of a MR imaging—derived classification for diagnosis of nerve root avulsion compared with those of myelography combined with computerized tomography (CT) myelography. Methods. The overlapping coronal—oblique slice MR imaging procedure was performed in 35 patients with traumatic brachial plexus injury and 10 healthy individuals. The results were retrospectively evaluated and classified into four major categories (normal rootlet, rootlet injuries, avulsion, and meningocele) after confirming the diagnosis by surgical exploration with or without spinal evoked potential (EP) measurements and by referring to myelography and CT myelography findings. The reliability and reproducibility of the MR imaging—based classification was prospectively assessed by eight independent observers, and its diagnostic accuracy was compared with that of traditional myelography/CT myelography classification, correlated with surgical and spinal EP findings in another 50 cervical roots in 10 patients with traumatic brachial plexus injury. Conclusions. In the retrospective study in which MR imaging and myelography/CT myelography findings involving 175 cervical roots in 35 patients were compared, the sensitivity of detection of the cervical nerve root avulsion was the same (92.9%) with both modalities. In the prospective study, interobserver reliability and intraobserver reproducibility showed that there was no statistically significant difference between MR imaging and myelography/CT myelography and that their accuracy for detecting cervical root avulsion was the same as that in the retrospective study. The overlapping coronal—oblique slice MR imaging technique is a reliable and reproducible method for detecting nerve root avulsion. The information provided by this modality enabled the authors to assess the roots of the brachial plexus and provided valuable data for helping to decide whether to proceed with exploration, nerve repair, primary reconstruction, or other imaging modalities.Keywords
This publication has 16 references indexed in Scilit:
- Magnetic Resonance Myelography in Brachial Plexus InjuryThe Journal of Bone and Joint Surgery. British volume, 1997
- Diagnosis of root avulsions in traumatic brachial plexus injuries: value of computerized tomography myelography and magnetic resonance imagingJournal of Neurosurgery, 1997
- Fast spin—echo magnetic resonance imaging for radiological assessment of neonatal brachial plexus injuryJournal of Neurosurgery, 1995
- Clinical, electrophysiological, and myelographic studies of 9 patients with cervical spinal root avulsions: Discrepancies between EMG and X-ray findingsMuscle & Nerve, 1994
- The Diagnostic Value of MRI in Traumatic Brachial Plexus InjuryJournal of Hand Surgery (European Volume), 1994
- Nerve root avulsion of birth palsy: comparison of myelography with CT myelography and somatosensory evoked potential.Radiology, 1991
- Usefulness of Myelography in Brachial Plexus InjuriesJournal of Hand Surgery (European Volume), 1989
- Cervical myelography of nerve root avulsion injuries using water-soluble contrast mediaBritish Journal of Radiology, 1988
- Normal brachial plexus: MR imaging.Radiology, 1987
- Traumatic dural tears: CT diagnosis using metrizamide.Radiology, 1984