This paper investigates the accuracy of the estimation of efficiency maps for permanent magnet (PM) machines using the stator resistance, d- and q-axis flux-linkages versus the corresponding axis current and the iron loss versus speed characteristic. The ultimate goal is to apply this approach to experimental measurements but this paper performs initial investigation using only finite-element data. Detailed FE data for 50-kW surface and interior PM machines is used to determine the “actual” or exact efficiency map and hence the accuracy of using approximations. The paper examines the effect on the torque-speed capability curve when ignoring cross-saturation effects. It also examines the modelling of the variation of iron losses as a function of load in the constant torque and power regions. A novel approach based on scaling the no-load losses as a function of load is proposed and shown to give promising results. Finite-element results from two other machines are also provided which show good correspondence.