Spatial Differences among Micropollutants in Sewer Overflows: A Multisite Analysis Using Passive Samplers
Authors:
- Lena MutznerLena Mutzner
- Simon DichtSDSimon Dicht
- Christoph OrtChristoph Ort
- 30 March 2020
- journal article
- research article
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 54 (11) , 6584-6593
Abstract
Untreated sewer overflows can contaminate receiving waters with micropollutants. Although concentrations of discharged micropollutants can be ecotoxicologically relevant, only limited data is available to assess occurrence and spatial differences among sewer overflow catchments. Therefore, we present an innovative type of data obtained with passive samplers at 20 combined sewer overflow sites (2–7 events per site; 95 events in total). The data sheds light on concentration ranges for 13 representative polar organic micropollutants and shows that micropollutants in both municipal wastewater and stormwater can be relevant sources of contaminants. We identify indicator micropollutants for further studies: benzotriazole (80% interquantile of time-weighted average concentration: 250–4,800 ng/L), carbamazepine (33–910 ng/L), diclofenac (78–1,000 ng/L), carbendazim (21–900 ng/L), diazinon (2.1–53 ng/L), diuron (22–1,100 ng/L), mecoprop (198–5,300 ng/L), metolachlor (6–230 ng/L), and terbutryn (29–810 ng/L). These concentration estimates are assumed to be on the safe side for comparison with environmental quality standards (EQS). A majority of sewer overflow sites (13 of 20) show discharge concentrations above acute EQS for at least one micropollutant and thus would have to rely on dilution by receiving waters to not exceed any EQS. The intersite variability among sewer overflows exceed the within-site variability. Hence, future monitoring studies should cover more sewer overflow sites. No correlation could be found with event durations, specific storage volume or land use data, thus showing the complexity of micropollutant occurrence and indicating that other factors led to the observed high spatial variability. In conclusion, our results clearly show the potential relevance of micropollutants in sewer overflows and the need to assess site-specific measures.Keywords
Funding Information
- Bundesamt f?r Umwelt (00.0102.PZ/P401-1414)
This publication has 29 references indexed in Scilit:
- Passive samplers to quantify micropollutants in sewer overflows: accumulation behaviour and field validation for short pollution eventsWater Research, 2019
- Passive samplers in sewers and rivers with highly fluctuating micropollutant concentrations – Better than we thoughtJournal of Hazardous Materials, 2019
- Model-based screening for critical wet-weather discharges related to micropollutants from urban areasWater Research, 2016
- Organic micropollutants discharged by combined sewer overflows – Characterisation of pollutant sources and stormwater-related processesWater Research, 2016
- A model library for dynamic transport and fate of micropollutants in integrated urban wastewater and stormwater systemsEnvironmental Modelling & Software, 2014
- Micropollutants in urban stormwater: occurrence, concentrations, and atmospheric contributions for a wide range of contaminants in three French catchmentsEnvironmental Science and Pollution Research, 2013
- Priority pollutants in urban stormwater: Part 2 – Case of combined sewersWater Research, 2012
- Combined Sewer Overflows: An Environmental Source of Hormones and Wastewater MicropollutantsEnvironmental Science & Technology, 2012
- An emission time series generator for pollutant release modelling in urban areasEnvironmental Modelling & Software, 2010
- Stormwater pollutant loads modelling: epistemological aspects and case studies on the influence of field data sets on calibration and verificationWater Science & Technology, 2007