Measuring thermal spread during bipolar cauterizing using an experimental pneumoperitoneum and thermal sensors
Open Access
- 13 June 2023
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Surgery
- Vol. 10, 1115570
Abstract
Objective: During nerve-sparing robot-assisted radical prostatectomy (RARP) bipolar electrocoagulation is often used but its use is controversial for the possible thermal damage of neurovascular bundles. Aim of the study was to evaluate the spatial-temporal thermal distribution in the tissue and the correlation with the electrosurgery-induced tissue damage in a controlled, CO2-rich environment modelling the laparoscopy conditions..Methods: We manufactured a sealed plexiglass chamber (SPC) equipped with sensors to reproduce experimentally the environmental conditions of pneumoperitoneum during RARP. We evaluated in 64 pig musculofascial tissues (PMTs) of approximately 3 cm3 × 3 cm3 × 2 cm3 the spatial-temporal thermal distribution in the tissue and the correlation with the electrosurgery-induced tissue damage in a controlled CO2-rich environment modeling the laparoscopy conditions. Critical heat spread of bipolar cauterizing during surgical procedure was assessed by the employment of a compact thermal camera (C2) with a small core sensor (60 × 80 microbolometer array in the range 7–14 μm).Results: Bipolar instruments used at 30 W showed a thermal spread area of 18 mm2 when applied for 2 s and 28 mm2 when applied for 4 s. At 60 W, bipolar instruments showed a mean thermal spread and 19 mm2 when applied for 2 s; and 21 mm2 when applied for 4 s. Finally, histopathological analysis showed that thermal damage is distributed predominantly on the surface rather than in depth.Conclusions: The application of these results is very interesting for the definition of an accurate use of bipolar cautery during nerve-sparing RARP. It demonstrates the feasibility of using miniaturized thermal sensors, thus addressing the potential for next developments regarding the design of thermal endoscopic devices for robotic use.Keywords
This publication has 16 references indexed in Scilit:
- A Critical Analysis of the Long-Term Impact of Radical Prostatectomy on Cancer Control and Function OutcomesEuropean Urology, 2012
- Comparison of Lateral Thermal Spread Using Monopolar and Bipolar Diathermy, and the Bipolar Vessel Sealing System ThermoStapler™ During ThyroidectomyPolish Journal of Surgery, 2011
- Comparison of lateral thermal spread using monopolar and bipolar diathermy, the Harmonic Scalpel™ and the Ligasure™British Journal of Surgery, 2010
- Evaluation of Long-Term Thermal Injury Using Cautery During Nerve Sparing Robotic ProstatectomyUrology, 2008
- Spread of Thermal Energy and Heat Sinks: Implications for Nerve-Sparing Robotic ProstatectomyJournal of Endourology, 2007
- 5-YEAR URINARY AND SEXUAL OUTCOMES AFTER RADICAL PROSTATECTOMY: RESULTS FROM THE PROSTATE CANCER OUTCOMES STUDYJournal of Urology, 2005
- Feasibility study for robotic radical prostatectomy cautery-free neurovascular bundle preservationUrology, 2005
- Comparison of Thermal Spread after Ureteral Ligation with the Laparo-Sonic™ Ultrasonic Shears and the Ligasure™ SystemJournal of Laparoendoscopic & Advanced Surgical Techniques, 2002
- Comparison of Coagulation Modalities in SurgeryJournal of Laparoendoscopic & Advanced Surgical Techniques, 1998
- Effects of Local Hyperthermia on the Motor Function of the Rat Sciatic NerveInternational Journal of Radiation Biology, 1988