Measurement system that improves the accuracy of polyp size determined at colonoscopy
Authors:
Open Access
- 21 February 2015
- journal article
- research article
- Published by Baishideng Publishing Group Inc. in World Journal of Gastroenterology
- Vol. 21 (7) , 2178-2182
Abstract
AIM: To assess the accuracy of polyp size using an endoscopic lesion measurement system (ELMS). METHODS: The accuracy of polyp size assessment was compared among measurements acquired by visual estimation, disposable graduated biopsy forceps (DGBF; used as a “scale-plate”) and the ELMS. RESULTS: There were 192 polyps from 166 cases included in this study. The mean diameter of the post polypectomy measurement was 0.85 ± 0.53 cm (range: 0.2-3.0 cm). The mean diameter by visual estimation was 1.10 ± 0.53 cm, which was significantly different compared to the actual size of the polyp (P < 0.001). The mean diameters obtained using DGBF (0.87 ± 0.54 cm) and ELMS (0.85 ± 0.53 cm) did not significantly differ from the actual size of the polyp. The difference between the measurements from the ELMS and DGBF was not significant. CONCLUSION: Unlike visual estimations at colonoscopy, endoscopic graduated biopsy forceps and the endoscopic lesion measurement system are accurate methods to estimate polyp size.Keywords
This publication has 8 references indexed in Scilit:
- [Study on accuracy of endoscopic polyp size measurement by disposable graduated biopsy forceps].2013
- Endoscopic Mis-sizing of Polyps Changes Colorectal Cancer Surveillance RecommendationsDiseases of the Colon & Rectum, 2013
- Endoscopic Submucosal Dissection for Early Colorectal Neoplasms: Clinical Experience in a Tertiary Medical Center in TaiwanGastroenterology Research and Practice, 2013
- Diagnosis of laterally spreading tumors (LST) in the rectum and selection of treatment: Characteristics of each of the subclassifications of LST in the rectumDigestive Endoscopy, 2013
- Tumor size as a prognostic factor in patients with advanced gastric cancer in the lower third of the stomachWorld Journal of Gastroenterology, 2012
- Endoscopic treatment for early stage colorectal tumors: The comparison between EMR with small incision, simplified ESD, and ESD using the standard Flush knife and the ball tipped Flush knifeActa chirurgica Iugoslavica, 2010
- Is in vivo measurement of size of polyps during colonoscopy accurate?Gastrointestinal Endoscopy, 1997
- The difference in colon polyp size before and after removalGastrointestinal Endoscopy, 1996