Multisite Comparison of Mucociliary and Cough Clearance Measures Using Standardized Methods
- 1 June 2013
- journal article
- research article
- Published by SAGE Publications in Journal of Aerosol Medicine and Pulmonary Drug Delivery
- Vol. 26 (3) , 157-164
Abstract
Background: A standardized protocol for measuring mucociliary (MCC) and cough clearance (CC) was developed and tested at the University of North Carolina at Chapel Hill, NC (UNC), Johns Hopkins University (JHU), and the University of Pittsburgh (Pitt). Methods: A total of 50 healthy nonsmoking adults with normal lung function were studied at the three sites: 30 [21 males/9 females (21M/9F)] at UNC, 10 (6M/4F) at JHU, and 10 (4M/6F) at Pitt. Subjects inhaled an aerosol of 99mtechnetium sulfur colloid in 0.9% saline (mass median aerodynamic diameter=5.4 μm) under controlled breathing conditions (500 mL/sec, 30 breaths/min) by following a metronome and flow signal from a commercial dosimeter. Following inhalation, subjects sat in front of a gamma camera as sequential lung images were acquired for 60 min. Subjects then coughed 60 times, and images were acquired after each set of 20 coughs, i.e., at 70, 80, and 90 min. Subjects returned to the laboratory approximately 24 hr later for a final image of residual lung activity. Initial aerosol distribution was measured as a central/peripheral (C/P) ratio of activity. MCC/CC was expressed as the area under the retention versus time curve over 90 min (AUC90). Results: A multivariate analysis of clearance versus time with site and C/P as covariates showed no significant site-specific differences. Interestingly, MCC/CC was greater in females (n=19) versus males (n=31), with AUC90=0.84±0.11 and 0.90±0.07, respectively (p=0.03), for the combined data set from all sites (not significant for any given site). There were no gender differences for either C/P ratio or 24-hr clearance. Conclusions: This standardized protocol may prove beneficial in multicenter trials for testing new therapies that are designed to improve MCC/CC.Keywords
This publication has 25 references indexed in Scilit:
- Targeting Aerosolized Drugs to the Conducting Airways Using Very Large Particles and Extremely Slow InhalationsJournal of Aerosol Medicine and Pulmonary Drug Delivery, 2010
- Mucociliary and Cough Clearance as a Biomarker for Therapeutic DevelopmentJournal of Aerosol Medicine and Pulmonary Drug Delivery, 2010
- Evidence for dysanapsis using computed tomographic imaging of the airways in older ex-smokersJournal of Applied Physiology, 2009
- Effect of increasing doses of mannitol on mucus clearance in patients with bronchiectasisEuropean Respiratory Journal, 2007
- PROLONGED AIRWAY RETENTION OF INSOLUBLE PARTICLES IN CYSTIC FIBROSIS VERSUS PRIMARY CILIARY DYSKINESIAExperimental Lung Research, 2000
- No effect of gender on lung mucociliary clearance in young healthy adultsRespiratory Medicine, 1994
- Relationship between Tracheobronchial Particle Clearance Rates and Sites of Initial Deposition in ManArchives of Environmental Health: An International Journal, 1989
- Intercomparison of Experimental Regional Aerosol Deposition DataJournal of Aerosol Medicine, 1989
- The Relationships of Aerosol Deposition, Lung Size, and the Rate of Mucociliary ClearanceArchives of Environmental Health: An International Journal, 1986
- The characterization of radioaerosol deposition in the healthy lung by histogram distribution analysisChest, 1981