Accurate PET/MR Quantification Using Time of Flight MLAA Image Reconstruction
- 16 January 2014
- journal article
- research article
- Published by Springer Nature in Molecular Imaging and Biology
- Vol. 16 (4) , 469-477
Abstract
Purpose Quantification of positron emission tomography/magnetic resonance imaging (PET/MRI) studies is hampered by inaccurate MR-based attenuation correction (MR-AC). To date, most studies on MR-AC have been performed using PET/MR systems without time of flight (TOF). Maximum likelihood reconstruction of attenuation and activity (MLAA), however, has the potential to improve MR-AC by exploiting TOF. The purpose of this study is to assess the impact of MR-AC on PET image quantification for TOF-PET/MR systems and to evaluate PET accuracy when using TOF in combination with MLAA (TOF-MLAA). Procedures Simulations were designed to evaluate (1) the impact of MR-AC on PET quantification for different TOF windows (667, 500, 333 and 167 ps) and (2) use of TOF-MLAA for improving PET quantification. TOF-ordered subset expectation maximisation (OSEM) and TOF-MLAA reconstructions using MR-AC were compared with those obtained using TOF-OSEM with computed tomography-based AC (CT-AC). Results OSEM reconstructions without TOF showed a negative MR-AC-induced bias of −50 % in the bone. TOF-OSEM was able to reduce this bias down to −15 %, with more accurate results for better TOF. TOF-MLAA was able to reduce the bias to within 5 % but at the cost of a ∼40 % increase in image variance. Conclusions TOF-MLAA can improve quantitative PET accuracy of PET/MR studies. Further improvements are anticipated with improving TOF performance.Keywords
This publication has 35 references indexed in Scilit:
- MR-Based PET Attenuation Correction for PET/MR ImagingSeminars in Nuclear Medicine, 2013
- MRI-guided attenuation correction in whole-body PET/MR: assessment of the effect of bone attenuationAnnals of Nuclear Medicine, 2012
- Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR ScannerJournal of Nuclear Medicine, 2011
- Simultaneous Reconstruction of Activity and Attenuation for PET/MRIEEE Transactions on Medical Imaging, 2010
- Toward Implementing an MRI-Based PET Attenuation-Correction Method for Neurologic Studies on the MR-PET Brain PrototypeJournal of Nuclear Medicine, 2010
- MRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time SequencesJournal of Nuclear Medicine, 2010
- Combined PET/MR Imaging — Technology and ApplicationsTechnology in Cancer Research & Treatment, 2010
- A decade of combined imaging: from a PET attached to a CT to a PET inside an MREuropean Journal of Nuclear Medicine and Molecular Imaging, 2008
- Towards quantitative PET/MRI: a review of MR-based attenuation correction techniquesEuropean Journal of Nuclear Medicine and Molecular Imaging, 2008
- Effects of noise, image resolution, and ROI definition on the accuracy of standard uptake values: a simulation study.2004