Prototype heel effect compensation filter for cone-beam CT
Authors:
- Shinichiro MoriSMShinichiro Mori
- Masahiro EndoMEMasahiro Endo
- Kanae NishizawaKNKanae Nishizawa
- Mari OhnoMOMari Ohno
- Hiroaki MiyazakiHMHiroaki Miyazaki
- Kazuhiko TsujitaKTKazuhiko Tsujita
- Yasuo SaitoYSYasuo Saito
- 1 November 2005
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 50 (22) , N359-N370
Abstract
The prototype cone-beam CT (CBCT) has a larger beam width than the conventional multi-detector row CT (MDCT). This causes a non-uniform angular distribution of the x-ray beam intensity known as the heel effect. Scan conditions for CBCT tube current are adjusted on the anode side to obtain an acceptable clinical image quality. However, as the dose is greater on the cathode side than on the anode side, the signal-to-noise ratio on the cathode side is excessively high, resulting in an unnecessary dose amount. To compensate for the heel effect, we developed a heel effect compensation (HEC) filter. The HEC filter rendered the dose distribution uniform and reduced the dose by an average of 25% for free air and by 20% for CTDI phantoms compared to doses with the conventional filter. In addition, its effect in rendering the effective energy uniform resulted in an improvement in image quality. This new HEC filter may be useful in cone-beam CT studies.Keywords
This publication has 12 references indexed in Scilit:
- Enlarged longitudinal dose profiles in cone‐beam CT and the need for modified dosimetryMedical Physics, 2005
- Physical performance evaluation of a 256‐slice CT‐scanner for four‐dimensional imagingMedical Physics, 2004
- X‐ray scatter correction algorithm for cone beam CT imagingMedical Physics, 2004
- Development and performance evaluation of the first model of 4-D CT-scannerIEEE Transactions on Nuclear Science, 2003
- An in‐phantom dosimetry system using pin silicon photodiode radiation sensors for measuring organ doses in x‐ray CT and other diagnostic radiologyMedical Physics, 2002
- Large-area two-dimensional detector for real-time three-dimensional CT (4D CT)2001
- Angular weighted hybrid cone-beam CT reconstruction for circular trajectoriesPhysics in Medicine & Biology, 2001
- Computed Tomography Dose Assessment - A Practical ApproachRadiation Protection Dosimetry, 1995
- In vivo evaluation of a new system for 3D computerized angiographyPhysics in Medicine & Biology, 1994
- Practical cone-beam algorithmJournal of the Optical Society of America A, 1984