GlideScope ® vs flexible fibreoptic scope for elective intubation in obese patients*
Open Access
- 13 May 2011
- journal article
- research article
- Published by Wiley in Anaesthesia
- Vol. 66 (7) , 550-555
Abstract
Summary: We hypothesised that in obese patients, tracheal intubation with the GlideScope ® would be advantageous compared with flexible fibreoptic intubation. Seventy‐five anaesthetised obese patients were randomly assigned to oral intubation by either GlideScope or flexible fibreoptic bronchoscope. We compared the two devices for time to intubate (p = 0.19), difficulty of intubation (p = 0.58), successful intubation on first attempt (p = 0.29), number of attempts (p = 0.24), incidence of hypoxaemia (p = 0.57), amount of post‐intubation bleeding (p = 0.79) and sore throat (p = 0.82). None differed significantly. Median (IQR [range]) time to intubation was 37 (25–48 [19–81]) s and 95% of the first attempts were successful with the GlideScope, vs 43 (35–58 [26–96]) s and an 86% first‐attempt success rate with the flexible fibreoptic bronchoscope. For experienced users, the time required to intubate the trachea in anaesthetised obese patients is similar with the GlideScope and a flexible bronchoscope.Keywords
This publication has 30 references indexed in Scilit:
- A comparison of a flexometallic tracheal tube with the intubating laryngeal mask tracheal tube for nasotracheal fibreoptic intubation using the two‐scope technique*Anaesthesia, 2009
- Fibreoptic and Videoscopic Indirect Intubation Techniques for Intubation in ChildrenPediatric Emergency Care, 2009
- Review of video laryngoscopy and rigid fiberoptic laryngoscopyCurrent Opinion in Anaesthesiology, 2008
- The Importance of Increased Neck Circumference to Intubation Difficulties in Obese PatientsAnesthesia & Analgesia, 2008
- Comparison of haemodynamic responses to orotracheal intubation with GlideScope® videolaryngoscope and fibreoptic bronchoscopeEuropean Journal of Anaesthesiology, 2006
- Determination of the site of tracheal tube impingement during nasotracheal fibreoptic intubation*Anaesthesia, 2006
- The use of a gum elastic bougie in combination with a videolaryngoscopeJournal of Clinical Anesthesia, 2005
- The Glidescope ® system: a clinical assessment of performanceAnaesthesia, 2004
- Difficult Airway Society guidelines for management of the unanticipated difficult intubationAnaesthesia, 2004
- The Parker Flex-Tip Tube versus a Standard Tube for Fiberoptic Orotracheal IntubationAnesthesiology, 2003