Portable and label-free quantitative Loop-mediated Isothermal Amplification (qLAMP) for reliable COVID-19 diagnostics in 3 minutes: An Arduino-based detection system assisted by a pH microelectrode
Preprint
Abstract
Loop-mediated isothermal amplification (LAMP) has been recently studied as an alternative method for cost-effective diagnostics in the context of the current COVID-19 pandemic. Recent reports document that LAMP-based diagnostic methods have a comparable sensitivity and specificity to that of RT-qPCR. We report the use of a portable Arduino-based LAMP-based amplification system assisted by pH microelectrodes for the accurate and reliable diagnosis of SARS-CoV-2 during the first 3 minutes of the amplification reaction. We show that this simple system enables a straightforward discrimination between samples containing or not containing artificial SARS-CoV-2 genetic material in the range of 10 to 10,000 copies per 50 µL of reaction mix. We also spiked saliva samples with SARS-CoV-2 synthetic material and corroborated that the LAMP reaction can be successfully monitored in real time using microelectrodes in saliva samples as well. These results may have profound implications for the design of real-time and portable quantitative systems for the reliable detection of viral pathogens including SARS-CoV-2.Keywords
All Related Versions
- Published version: Biosensors, 11 (10), 386.
This publication has 35 references indexed in Scilit:
- Pullulan reduces the non-specific amplification of loop-mediated isothermal amplification (LAMP)Analytical and Bioanalytical Chemistry, 2019
- Loop-mediated isothermal amplification (LAMP): a versatile technique for detection of micro-organismsJournal of Applied Microbiology, 2018
- Screen-Printed Polyaniline-Based Electrodes for the Real-Time Monitoring of Loop-Mediated Isothermal Amplification ReactionsAnalytical Chemistry, 2017
- Microscale loop-mediated isothermal amplification of viral DNA with real-time monitoring on solution-gated graphene FET microchipBiosensors and Bioelectronics, 2017
- Visual Detection of Isothermal Nucleic Acid Amplification Using pH-Sensitive DyesBioTechniques, 2015
- Saliva pH as a biomarker of exam stress and a predictor of exam performanceJournal of Psychosomatic Research, 2014
- Using the ubiquitous pH meter combined with a loop mediated isothermal amplification method for facile and sensitive detection of Nosema bombycis genomic DNA PTP1Chemical Communications, 2014
- Simultaneous DNA amplification and detection using a pH-sensing semiconductor systemNature Methods, 2013
- Salivary pH: A diagnostic biomarkerJournal of Indian Society of Periodontology, 2013
- An integrated semiconductor device enabling non-optical genome sequencingNature, 2011