Low compression smart clothing for respiratory rate monitoring using a bending angle sensor based on double-layer capacitance
Open Access
- 18 January 2025
- journal article
- research article
- Published by Springer Nature in Biomedical Engineering Letters
- Vol. 15 (2) , 389-399
Abstract
In chronic respiratory diseases, continuous self-monitoring of vital signs such as respiratory rate aids in the early detection of exacerbations. In recent years, the development of smart clothing, such as garments equipped with sensors to measure respiratory rate, has been a focus of research. However, the usability and adoption of smart clothing are often compromised owing to the discomfort caused by compression pressure during wear. This study developed smart clothing designed to measure respiratory rate using a low compression pressure. This was achieved by integrating a bending angle sensor, based on double-layer capacitance, into the rib cage and abdomen areas. The accuracy of the respiratory rate measurement was evaluated in 20 healthy male subjects without respiratory diseases. Breathing was measured while the subjects wore the smart clothing and performed breathing exercises in sitting, supine, and lateral postures, following a metronome set between 12 and 30 bpm. To assess accuracy, the respiratory rate measured by the smart clothing was compared with that measured by a spirometer. The recorded compression pressure was 0.77 ± 0.21 kPa, with no subjects reporting discomfort. Correlation coefficients for respiratory rate in the different postures ranged within 0.97–0.99. The mean difference between the smart clothing and spirometer measurements was less than 0.1 bpm. The low mean difference indicated that the proposed low compression pressure wearable respiration sensor, employing a bending angle sensor based on double-layer capacitance, could measure respiratory rate accurately without causing discomfort and within an acceptable error range.Keywords
Funding Information
- Ritsumeikan University
This publication has 36 references indexed in Scilit:
- Biosignal Monitoring Clothing System for the Acquisition of ECG and Respiratory SignalsIEEE Access, 2022
- Contactless Respiration and Heartbeat Monitoring of Multiple People Using a 2-D Imaging Radar2019
- Design and Development of a IoT based Flexible and Wearable T-Shirt for Monitoring Breathing Rate2019
- Respiratory Waveform Estimation From Multiple Accelerometers: An Optimal Sensor Number and Placement AnalysisIEEE Journal of Biomedical and Health Informatics, 2018
- Smart textile for respiratory monitoring and thoraco‐abdominal motion pattern evaluationJournal of Biophotonics, 2018
- Continuous Monitoring in an Inpatient Medical-Surgical Unit: A Controlled Clinical TrialThe American Journal of Medicine, 2014
- Effects of gender and posture on thoraco-abdominal kinematics during quiet breathing in healthy adultsRespiratory Physiology & Neurobiology, 2010
- The Economic Burden of Non–Influenza-Related Viral Respiratory Tract Infection in the United StatesArchives of internal medicine (1960), 2003
- Respiratory rate measurement in adults—how reliable is it?Respiratory Medicine, 2002
- Impact of Chronic Cough on Quality of LifeArchives of internal medicine (1960), 1998