Arterial Spin–Labeled Perfusion Imaging to Predict Mismatch in Acute Ischemic Stroke

Authors:

Abstract
Background and Purpose—: We assigned a threshold to arterial spin–labeling (ASL) perfusion-weighted images (PWI) from patients with acute ischemic stroke and compared them with dynamic susceptibility contrast perfusion images to examine whether mismatch can be determined. Methods—: Pseudocontinuous ASL was combined with dynamic susceptibility contrast PWI in 23 patients with acute ischemic stroke. Scans were obtained within 24 hours of symptom onset. PWI volumes were defined by ASL cerebral blood flow (<15, <20, and 10 s) that show a strong association with cerebral blood flow 10 s and ASL10 s and ASL<20 mL/100 g per minute. The correlation between infarct growth and penumbra salvage volume was significantly better for PWI lesions defined by ASL10 s. Conclusions—: In acute ischemic stroke, PWI lesions based on ASL threshold of 10 s.

This publication has 10 references indexed in Scilit: