A Robust Ultrashort TE (UTE) Imaging Method With Corrected k-Space Trajectory by Using Parametric Multiple Function Model of Gradient Waveform
- 24 October 2012
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 32 (2) , 306-316
Abstract
Ultra-short TE (UTE) sequences with radial sampling make it possible to visualize tissues with very short T2 decay times. The UTE sequence acquires an echo signal from the central to the outer parts of k-space and is very sensitive to small trajectory errors. Therefore, k-space errors caused by imperfections in the gradient system performance, such as gradient delay and waveform distortion, must be corrected. During normal clinical use, these errors must be corrected to account for any gradient strength, or image obliquity. Because of time limitation on clinical examination, a simple, robust, and time-efficient correction method for use with UTE is needed. We demonstrated image degradation due to k-space errors by simulation and found that uncontrolled gradient time delays were the dominant cause of image degradation. They could be corrected by using a pre-scan calibration that works by comparison of half and full echo signals. Further improvements in image quality were achieved by using a one-time calibration of gradient waveform approximations that were built from multiple exponential functions and were used during image reconstruction. We have developed a robust UTE correction method that consists of a gradient waveform approximation that follows a short pre-scan for estimating gradient time delay errors.Keywords
This publication has 15 references indexed in Scilit:
- Fast, simple gradient delay estimation for spiral MRIMagnetic Resonance in Medicine, 2010
- Characterizing and correcting gradient errors in non‐cartesian imaging: Are gradient errors linear time‐invariant (LTI)?Magnetic Resonance in Medicine, 2009
- Estimation of k‐space trajectories in spiral MRIMagnetic Resonance in Medicine, 2009
- Magnetic resonance imaging with ultrashort TE (UTE) PULSE sequences: Technical considerationsJournal of Magnetic Resonance Imaging, 2007
- Magnetic resonance imaging of entheses using ultrashort TE (UTE) pulse sequencesJournal of Magnetic Resonance Imaging, 2007
- Clinical ultrashort echo time imaging of bone and other connective tissuesNMR in Biomedicine, 2006
- Magnetic resonance imaging of periosteum with ultrashort TE pulse sequencesJournal of Magnetic Resonance Imaging, 2003
- A Method to measure arbitrary k‐space trajectories for rapid MR imagingMagnetic Resonance in Medicine, 1997
- Projection Reconstruction Techniques for Reduction of Motion Effects in MRIMagnetic Resonance in Medicine, 1992
- Selection of a convolution function for Fourier inversion using gridding (computerised tomography application)IEEE Transactions on Medical Imaging, 1991