Abstract
The electrical breakdown is investigated in high‐density polyethylene/graphite nanosheets (HDPE/GNs) conductive composites. A sample suffers electrical breakdown when the applied field exceeds the critical electrical breakdown field below which the sample reaches a stable state. It is found that the ratio of the critical electrical breakdown resistance to the linear resistance assumes a fixed value Y, which is found to be about 1.30 in HDPE/GNs conductive composites. The value Y is independent of GNs' content, sample size, breakdown cycle, but depends on the property of GNs. The critical breakdown field Eb scales with the resistance R0 as $E_{\rm b}\sim R_0^{y_{\rm b}}$ with the exponent yb = 0.46 ± 0.02, which is close to the value predicted in mean‐field theory but higher than the value given by the singly connected bonds networks. © 2009 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys 47: 576–582, 2009

This publication has 24 references indexed in Scilit: