Device and Imaging-Specific Volumetric Analysis of Clot Lysis After Percutaneous Mechanical Thrombectomy for Iliofemoral DVT
Authors:
- 1 June 2010
- journal article
- research article
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 17 (3) , 423-433
Abstract
Purpose: To determine the most accurate method of assessing clot lysis after percutaneous mechanical thrombectomy for iliofemoral deep vein thrombosis (DVT) and to evaluate the effectiveness of two different pharmacomechanical thrombectomy devices. Methods: Between 2004 and 2009, 33 patients (18 women; mean age 47 years) with iliofemoral DVT underwent pharmacomechanical thrombectomy using the AngioJet (n = 18) or Trellis (n = 15) devices with 10 mg of tenecteplase. Intravascular ultrasound (IVUS) and venography were performed over the iliofemoral segments before and after treatment. Cross-sectional vessel and lumen diameters were measured from the IVUS scans and the post-procedure anteroposterior and lateral venograms at 3 points (proximal, mid-section, and distal) along each iliofemoral vein by 2 independent observers blinded to the treatment method. Volumes of the recanalized segments were calculated and compared to volumes of the original venous segments to assess clot lysis with each PMT device. IVUS scans and venograms were also compared for their ability to identify residual lesions or clot in need of treatment. Repeatability between and among observers was analyzed using the Bland and Altman method. Results: All procedures were successfully completed; there were only 2 minor bleeding complications. The mean volume of the recanalized segment was 2255±66 mm3 by IVUS, representing 80% lysis of the clot compared to what was perceived as >90% lysis with venography (p3 and total venous segment volumes of 2826±84 and 2813±79 mm3, respectively. Conclusion: IVUS is superior to venography for detection of residual thrombus and underlying venous pathology after pharmacomechanical thrombectomy. While greater clot lysis was seen with the AngioJet system, both the AngioJet and Trellis devices resulted in excellent clinical clot lysis.Keywords
This publication has 19 references indexed in Scilit:
- Iliofemoral venous thrombosisJournal of Vascular Surgery, 2007
- Treatment of Acute Iliofemoral Deep Venous Thrombosis: A Strategy of Thrombus RemovalEuropean Journal of Vascular and Endovascular Surgery, 2007
- Catheter-directed thrombolysis for lower extremity deep vein thrombosisTechniques in Vascular and Interventional Radiology, 2001
- Catheter-directed Thrombolysis for Lower Extremity Deep Venous Thrombosis: Report of a National Multicenter RegistryRadiology, 1999
- Venous thrombectomy for lliofemoral vein thrombosis — 10-year results of a prospective randomised studyEuropean Journal of Vascular and Endovascular Surgery, 1997
- Long-term outcomes of deep-vein thrombosisArchives of internal medicine (1960), 1995
- Relationship between changes in the deep venous system and the development of the postthrombotic syndrome after an acute episode of lower limb deep vein thrombosis: A one- to six-year follow-upJournal of Vascular Surgery, 1995
- Venous function assessed during a 5 year period after acute ilio-femoral venous thrombosis treated with anticoagulationEuropean Journal of Vascular Surgery, 1990
- The socioeconomic effects of an iliofemoral venous thrombosisJournal of Surgical Research, 1977
- Surgical management of iliofemoral venous thrombosisThe American Journal of Surgery, 1966