Directional Overcurrent Protection Design for Distribution Network: CIGRE European Medium-Voltage Benchmark Network
Open Access
- 18 November 2024
- conference paper
- Published by MDPI AG in Engineering Proceedings
- Vol. 77 (1) , 26
Abstract
Overcurrent protection is a fundamental aspect of power system protection and is widely utilised in distribution networks. The increasing integration of renewable energy sources (RESs) into the conventional power system has introduced operating challenges due to the variability in fault directions. As a result, protection engineers must not only adjust basic parameters such as pickup current or time delay, but also carefully evaluate the directional protection to align with specific protection objectives and the devices being protected. The complexity of considering multiple aspects in the protection system design can pose challenges for operators in configuring their settings. Therefore, it is necessary to have a systematic approach for protection system design. For this purpose, this paper proposes a methodology for protection system design focusing on directional overcurrent protection setting configuration with detailed implementation. A well-known distribution network, the CIGRE European (EU) medium-voltage (MV) benchmark network, is used to test and validate the proposed methodology with the support of DIgSILENT PowerFactory version 2023 SP1. This article provides a useful document for the configuration of overcurrent protection systems in order to prepare for the challenges arising from the high integration of RESs in the future grid.Keywords
This publication has 21 references indexed in Scilit:
- Co-simulation-based optimal reactive power control in smart distribution networkElectrical Engineering, 2023
- Day-ahead energy-mix proportion for the secure operation of renewable energy-dominated power systemInternational Journal of Electrical Power & Energy Systems, 2023
- Distance Protection Relay Testing Using Virtual Hardware-in-the-Loop Device2023
- Non-directional Overcurrent Protection Relay Testing Using Virtual Hardware-in-the-Loop Device2023
- Power system coherency recognition and islanding: Practical limits and future perspectivesIET Energy Systems Integration, 2022
- A short communication to define the overcurrent protection system of the CIGRE European benchmark distribution networks for RES penetration studiesElectrical Engineering, 2021
- Sensitivity analysis of transient short circuit current response to the penetration level of non-synchronous generationInternational Journal of Electrical Power & Energy Systems, 2021
- Protection philosophy in low short‐circuit capacity distribution grids with high penetration of converter‐interfaced distributed renewable energy sourcesIET Generation, Transmission & Distribution, 2020
- IEEE standard inverse-time characteristic equations for overcurrent relaysIEEE Transactions on Power Delivery, 1999
- Coordination of directional overcurrent relay timing using linear programmingIEEE Transactions on Power Delivery, 1996