Clinical outcomes of complex lesions treated with an abluminal groove‐filled biodegradable polymer sirolimus‐eluting stent and durable polymer everolimus‐eluting stent
Authors:
- Yuichi SaitoYSYuichi Saito
- Bo XuBXBo Xu
- Richard AndersonRARichard Anderson
- Alexandra LanskyALAlexandra Lansky
- TARGET AC InvestigatorsTITARGET AC Investigators
- 25 November 2019
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 96 (5) , 1023-1028
Abstract
Background: The Firehawk stent (Shanghai MicroPort Medical Group, Shanghai, China), a novel biodegradable polymer sirolimus‐eluting coronary stent has been evaluated in the randomized TARGET I trial in which low‐risk patients were enrolled with strict eligibility criteria. Recently, the TARGET All Comers study has shown similar results of the Firehawk compared to the XIENCE stent (Abbott Vascular, Santa Clara). However, clinical outcomes in high‐risk patients are unclear.Methods: The TARGET All Comer study was a randomized trial that assigned patients to either Firehawk or XIENCE implantation. This TARGET AC subanalysis sought to evaluate the 2 year clinical outcomes of patients according to two risk groups; patients meeting all inclusion criteria and no exclusion criteria of the TARGET I trial were classified as “low‐risk,” while their counterparts were classified as “high‐risk.” The primary endpoint was target lesion failure.Results: A total of 1,585 patients were included, of which 1,334 (84%) were classified as high‐risk. At 2 years, the high‐risk group had a significantly higher rate of TLF than the low‐risk group (9.5% vs. 3.6%, p = .003), mainly driven by increased target vessel myocardial infarction (6.3% vs. 2.4%, p = .02). The Firehawk and XIENCE had no significant differences in TLF among both low‐risk (3.1% vs. 4.2%, p = .66) and high‐risk (9.9% vs. 9.1%, p = .57) patients.Conclusions: High‐risk patients had worse clinical outcomes at 2 years in the TARGET All Comer study. Outcomes with the Firehawk were similar to the XIENCE stent among both low‐risk and high‐risk patients at 2 years.Keywords
Funding Information
- SENSHIN Medical Research Foundation
This publication has 18 references indexed in Scilit:
- Safety and efficacy of a novel abluminal groove‐filled biodegradable polymer sirolimus‐eluting stent for the treatment of de novo coronary lesions: Two‐year results from a prospective patient‐level pooled analysis of TARGET trialsCatheterization and Cardiovascular Interventions, 2015
- Comparison of vascular response between durable and biodegradable polymer-based drug-eluting stents in a porcine coronary artery modelEuroIntervention, 2014
- 2014 ESC/EACTS Guidelines on myocardial revascularizationEuropean Heart Journal, 2014
- Pathology of Second-Generation Everolimus-Eluting Stents Versus First-Generation Sirolimus- and Paclitaxel-Eluting Stents in HumansCirculation, 2014
- A randomised comparison of a novel abluminal groove-filled biodegradable polymer sirolimus-eluting stent with a durable polymer everolimus-eluting stent: clinical and angiographic follow-up of the TARGET I trialEuroIntervention, 2013
- Evaluating the 'all-comers' design: a comparison of participants in two 'all-comers' PCI trials with non-participantsEuropean Heart Journal, 2011
- Myocardial infarction adjudication in contemporary all-comer stent trials: balancing sensitivity and specificityEuroIntervention, 2010
- Vascular Responses to Drug Eluting StentsArteriosclerosis, Thrombosis, and Vascular Biology, 2007
- Clinical End Points in Coronary Stent TrialsCirculation, 2007
- Pathology of Drug-Eluting Stents in HumansJACC, 2006